Investigation of fluorescence versus transmission readout for three-photon Rydberg excitation used in electrometry
arXiv:2402.00718 · doi:10.1116/5.0201928
Abstract
We present a three-photon based fluorescence readout method where the strength of the fluorescence scales with the strength of the radio-frequency (RF) field being applied. We compare this method to conventional three-photon electromagnetically-induced transparency (EIT) and electromagnetically-induced absorption (EIA). Our demonstrated EIA/EIT sensitivity in the collinear three-photon Cesium system is the best reported to date at roughly 30 uVm^{-1}Hz^{-1/2}. The fluorescence is nearly 4 fold better in sensitivity compared to EIA/EIT readout.
9 figure, quantum optics, rydberg electrometry
References in corpus (11)
- Broadband Rydberg Atom-Based Electric-Field Probe: From Self-Calibrated Measurements to Sub-Wavelength Imaging
- Waveguide-coupled Rydberg spectrum analyzer from 0 to 20 GHz
- Determining the Angle-of-Arrival of an Radio-Frequency Source with a Rydberg Atom-Based Sensor
- Continuous wideband microwave-to-optical converter based on room-temperature Rydberg atoms
- Quantum Physics Meets Music: A "Real-Time" Guitar Recording Using Rydberg-Atoms and Electromagnetically Induced Transparency
- Electromagnetically induced transparency based Rydberg-atom sensor for quantum voltage measurements
- TV and Video Game Streaming with a Quantum Receiver: A Study on a Rydberg atom-based receivers bandwidth and reception clarity
- Quantum Blackbody Thermometry
- Sensitivity Comparison of Two-photon vs Three-photon Rydberg Electrometry
- Improvement of response bandwidth and sensitivity of Rydberg Receiver using multi-channel excitations
- Single-photon cesium Rydberg excitation spectroscopy using 318.6-nm UV laser and room-temperature vapor cell