Improving the stability of frequency dependent squeezing with bichromatic control of filter cavity length, alignment and incident beam pointing
arXiv:2203.10815 · doi:10.1103/PhysRevD.105.082003
Abstract
Frequency dependent squeezing is the main upgrade for achieving broadband quantum noise reduction in upcoming observation runs of gravitational wave detectors. The proper frequency dependence of the squeezed quadrature is obtained by reflecting squeezed vacuum from a Fabry-Perot filter cavity detuned by half of its linewidth. However, since the squeezed vacuum contains no classical amplitude, co-propagating auxiliary control beams are required to achieve the filter cavity's length, alignment, and incident beam pointing stability. In our frequency dependent squeezing experiment at the National Astronomical Observatory of Japan, we used a control beam at a harmonic of squeezed vacuum wavelength and found visible detuning variation related to the suspended mirrors angular drift. These variations can degrade interferometer quantum noise reduction. We investigated various mechanisms that can cause the filter cavity detuning variation. The detuning drift is found to be mitigated sufficiently by fixing the incident beam pointing and applying filter cavity automatic alignment. It was also found that there is an optimal position of the beam on the filter cavity mirror that helps to reduce the detuning fluctuations. Here we report a stabilized filter cavity detuning variation of less than 10Hz compared to the 113Hz cavity linewidth. Compared to previously published results [Phys. Rev. Lett. 124, 171101 (2020)], such detuning stability would be sufficient to make filter cavity detuning drift induced gravitational wave detector detection range fluctuation reduce from to within .
Accepted by PRD
References in corpus (10)
- Advanced Virgo: a 2nd generation interferometric gravitational wave detector
- Advanced LIGO
- GW190521: A Binary Black Hole Merger with a Total Mass of
- Sensitivity and Performance of the Advanced LIGO Detectors in the Third Observing Run
- Thermo-optic noise in coated mirrors for high-precision optical measurements
- Low-Latency Gravitational Wave Alerts for Multi-Messenger Astronomy During the Second Advanced LIGO and Virgo Observing Run
- Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise Reduction in Advanced Gravitational-Wave Detectors
- Multi-Material Coatings with Reduced Thermal Noise
- Prospects for improving the sensitivity of the cryogenic gravitational wave detector KAGRA
- An arm length stabilization system for KAGRA and future gravitational-wave detectors