Decoherence and degradation of squeezed states in quantum filter cavities
arXiv:1704.03531 · doi:10.1103/PhysRevD.90.062006
Abstract
Squeezed states of light have been successfully employed in interferometric gravitational-wave detectors to reduce quantum noise, thus becoming one of the most promising options for extending the astrophysical reach of the generation of detectors currently under construction worldwide. In these advanced instruments, quantum noise will limit sensitivity over the entire detection band. Therefore, to obtain the greatest benefit from squeezing, the injected squeezed state must be filtered using a long-storage-time optical resonator, or "filter cavity", so as to realise a frequency dependent rotation of the squeezed quadrature. Whilst the ultimate performance of a filter cavity is determined by its storage time, several practical decoherence and degradation mechanisms limit the experimentally achievable quantum noise reduction. In this paper we develop an analytical model to explore these mechanisms in detail. As an example, we apply our results to the 16 m filter cavity design currently under consideration for the Advanced LIGO interferometers.
References in corpus (2)
Cited by in corpus (41)
- Exploring the Sensitivity of Next Generation Gravitational Wave Detectors
- Squeezed states of light and their applications in laser interferometers
- Quantum correlations between the light and kilogram-mass mirrors of LIGO
- A Cryogenic Silicon Interferometer for Gravitational-wave Detection
- A Gravitational Wave Detector with Cosmological Reach
- Frequency-Dependent Squeezing for Advanced LIGO
- Prospects for doubling the range of Advanced LIGO
- Proposal for Gravitational-Wave Detection Beyond the Standard Quantum Limit via EPR Entanglement
- Advanced LIGO detector performance in the fourth observing run
- Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise Reduction in Advanced Gravitational-Wave Detectors
- Squeezing the quantum noise of a gravitational-wave detector below the standard quantum limit
- Review of the Advanced LIGO gravitational wave observatories leading to observing run four
- Gravitational-wave physics with Cosmic Explorer: limits to low-frequency sensitivity
- Prospects for detecting gravitational waves at 5 Hz with ground-based detectors
- Multi-Material Coatings with Reduced Thermal Noise
- Kilonova Emission From Black Hole-Neutron Star Mergers. II. Luminosity Function and Implications for Target-of-opportunity Observations of Gravitational-wave Triggers and Blind Searches
- LIGOs Quantum Response to Squeezed States
- Gravitational wave detection beyond the standard quantum limit using a negative-mass spin system and virtual rigidity
- Estimation of losses in a 300 m filter cavity and quantum noise reduction in the KAGRA gravitational-wave detector
- Quantum limit for laser interferometric gravitational wave detectors from optical dissipation
- Quantum correlation measurements in interferometric gravitational wave detectors
- Prospects for improving the sensitivity of the cryogenic gravitational wave detector KAGRA
- Broadband sensitivity enhancement of detuned dual-recycled Michelson interferometers with EPR entanglement
- Measurement of optical losses in a high-finesse 300 m filter cavity for broadband quantum noise reduction in gravitational-wave detectors
- Multi-spatial-mode effects in squeezed-light-enhanced interferometric gravitational wave detectors
- Implications of the Quantum Noise Target for the Einstein Telescope Infrastructure Design
- Frequency-dependent squeezing for gravitational-wave detection through quantum teleportation
- Effect of squeezing on parameter estimation of gravitational waves emitted by compact binary systems
- Optimal detuning for quantum filter cavities
- An analysis and visualization of the output mode-matching requirements for squeezing in Advanced LIGO and future gravitational wave detectors
- Measurements of Optical Scatter Versus Annealing Temperature for Amorphous Ta2O5 and TiO2:Ta2O5 Thin Films
- Demonstration of an amplitude filter cavity at gravitational-wave frequencies
- Imaging Scatterometer for Observing In-Situ Changes to Optical Coatings During Air Annealing
- Fundamental sensitivity limit of lossy cavity-enhanced interferometers with external and internal squeezing
- Improving the stability of frequency dependent squeezing with bichromatic control of filter cavity length, alignment and incident beam pointing
- Control of a filter cavity with coherent control sidebands
- Enhancing the force sensitivity of squeezed light optomechanical interferometer
- Optical losses as a function of beam position on the mirrors in a 285-m suspended Fabry-Perot cavity
- Performance of multiple filter-cavity schemes for frequency-dependent squeezing in gravitational-wave detectors
- Demonstration of length control for a filter cavity with coherent control sidebands
- Probing squeezing for gravitational-wave detectors with an audio-band field