Low Gain Avalanche Detectors with Good Time Resolution Developed by IHEP and IME for ATLAS HGTD project
arXiv:2109.11209 · doi:10.1016/j.nima.2022.166604
Abstract
This paper shows the simulation and test results of 50um thick Low Gain Avalanche Detectors (LGAD) sensors designed by the Institute of High Energy Physics (IHEP) and fabricated by the Institute of Microelectronics of the Chinese Academy of Sciences (IME). Three wafers have been produced with four different gain layer implant doses each. Different production processes, including variation in the n++ layer implant energy and carbon co-implantation were used. Test results show that the IHEP-IME sensors with the higher dose of gain layer have lower breakdown voltages and higher gain layer voltages from capacitance-voltage properties, which are consistent with the TCAD simulation. Beta test results show that the time resolution of IHEP-IME sensors is better than 35ps when operated at high voltage and the collected charges of IHEP-IME sensors are larger than 15fC before irradiation, which fulfill the required specifications of sensors before irradiations for the ATLAS HGTD project.
arXiv comment11 pages,8 figures
References in corpus (7)
- Beam test results of a 16 ps timing system based on ultra-fast silicon detectors
- First FBK Production of 50m Ultra-Fast Silicon Detectors
- Development of a technology for the fabrication of Low-Gain Avalanche Detectors at BNL
- Layout and Performance of HPK Prototype LGAD Sensors for the High-Granularity Timing Detector
- Comparison of 35 and 50 μm thin HPK UFSD after neutron irradiation up to 6*10^15 neq/cm^2
- Radiation effects on NDL prototype LGAD sensors after proton irradiation
- Beam test results of IHEP-NDL Low Gain Avalanche Detectors(LGAD)