Johnson-Nyquist Noise Effects in Neutron Electric-Dipole-Moment Experiments
arXiv:2102.01658 · doi:10.1103/PhysRevA.103.062801
Abstract
Magnetic Johnson-Nyquist noise (JNN) originating from metal electrodes, used to create a static electric field in neutron electric-dipole-moment (nEDM) experiments, may limit the sensitivity of measurements. We present here the first dedicated study on JNN applied to a large-scale long-measurement-time experiment with the implementation of a co-magnetometry. In this study, we derive surface- and volume-averaged root-mean-square normal noise amplitudes at a certain frequency bandwidth for a cylindrical geometry. In addition, we model the source of noise as a finite number of current dipoles and demonstrate a method to simulate temporal and three-dimensional spatial dependencies of JNN. The calculations are applied to estimate the impact of JNN on measurements with the new apparatus, n2EDM, at the Paul Scherrer Institute. We demonstrate that the performances of the optically pumped Cs magnetometers and Hg co-magnetometers, which will be used in the apparatus, are not limited by JNN. Further, we find that in measurements deploying a co-magnetometer system, the impact of JNN is negligible for nEDM searches down to a sensitivity of in a single measurement; therefore, the use of economically and mechanically favored solid aluminum electrodes is possible.
References in corpus (17)
- Measurement of the permanent electric dipole moment of the neutron
- Impact of the Casimir-Polder Potential and Johnson Noise on Bose-Einstein Condensate Stability near Surfaces
- Thermally induced spin flips above an atom chip
- Calculation of Magnetic Field Noise from High-Permeability Magnetic Shields and Conducting Objects with Simple Geometry
- Performance of the upgraded ultracold neutron source at Los Alamos National Laboratory and its implication for a possible neutron electric dipole moment experiment
- Thermal spin flips in atom chips
- Apparatus for Measurement of the Electric Dipole Moment of the Neutron using a Cohabiting Atomic-Mercury Magnetometer
- Comparison of ultracold neutron sources for fundamental physics measurements
- Measurement of the trapping lifetime close to a cold metallic surface on a cryogenic atom-chip
- A highly stable atomic vector magnetometer based on free spin precession
- Magnetic field uniformity in neutron electric dipole moment experiments
- The n2EDM experiment at the Paul Scherrer Institute
- Magnetostatic field noise near metallic surfaces
- Neutron optics of the PSI ultracold neutron source: characterization and simulation
- The MCUCN simulation code for ultracold neutron physics
- Demonstration of sensitivity increase in mercury free-spin-precession magnetometers due to laser-based readout for neutron electric dipole moment searches
- Low magnetic Johnson noise electric field plates for precision measurement