Low magnetic Johnson noise electric field plates for precision measurement
arXiv:1608.02855 · doi:10.1063/1.4966991
Abstract
We describe a parallel pair of high voltage electric field plates designed and constructed to minimise magnetic Johnson noise. They are formed by laminating glass substrates with commercially available polyimide (Kapton) tape, covered with a thin gold film. Tested in vacuum, the outgassing rate is less than mbar.l/s. The plates have been operated at electric fields up to 8.3 kV/cm, when the leakage current is at most a few hundred pA. The design is discussed in the context of a molecular spin precession experiment to measure the permanent electric dipole moment of the electron.
arXiv comment9 pages, 3 figures
References in corpus (8)
- Order of Magnitude Smaller Limit on the Electric Dipole Moment of the Electron
- Loss and heating of particles in small and noisy traps
- Thermally induced spin flips above an atom chip
- Measurement of the electron's electric dipole moment using YbF molecules: methods and data analysis
- Design for a fountain of YbF molecules to measure the electron's electric dipole moment
- Prospects for measuring the electric dipole moment of the electron using electrically trapped polar molecules
- Measurement of the trapping lifetime close to a cold metallic surface on a cryogenic atom-chip
- A robust floating nanoammeter