Radiation damage assessment of SensL SiPMs
arXiv:2003.08213 · doi:10.1016/j.nima.2020.164798
Abstract
Silicon Photomultipliers (SiPMs) are quickly replacing traditional photomultiplier tubes (PMTs) as the readout of choice for gamma-ray scintillation detectors in space. While they offer substantial size, weight and power saving, they have shown to be susceptible to radiation damage. SensL SiPMs with different cell sizes were irradiated with 64 MeV protons and 8 MeV electrons. In general, results show larger cell sizes are more susceptible to radiation damage with the largest 50 um SiPMs showing the greatest increase in current as a function of dose. Current increases were observed for doses as low at ~2 rad(Si) for protons and ~20 rad(Si) for electrons. The U.S. Naval Research Laboratory's (NRL) Strontium Iodide Radiation Instrument (SIRI-1) experienced a 528 uA increase in the bias current of the on-board 2x2 SensL J-series 60035 SiPM over its one-year mission in sun-synchronous orbit. The work here focuses on the increase in bulk current observed with increasing radiation damage and was performed to better quantify this effect as a function of dose for future mission. These include the future NRL mission SIRI-2, the follow on to SIRI-1, Glowbug and the GAGG Radiation Instrument (GARI).
arXiv comment36 pages, 49 Figures, To be presented at the Nuclear and Space Radiation Effects Conference (NSREC 2020)
References in corpus (7)
- Radiation damage of SiPMs
- Radiation Hardness Tests of SiPMs for the JLab Hall D Barrel Calorimeter
- GRID: a Student Project to Monitor the Transient Gamma-Ray Sky in the Multi-Messenger Astronomy Era
- Radiation Damage Studies of Silicon Photomultipliers
- Radiation Damage Study of SensL J-Series Silicon Photomultipliers Using 101.4 MeV Protons
- Proton Irradiation Damage and Annealing Effects in ON Semiconductor J-Series Silicon Photomultipliers
- Analysis methods for highly radiation-damaged SiPMs
Cited by in corpus (9)
- The All-sky Medium Energy Gamma-ray Observatory eXplorer (AMEGO-X) Mission Concept
- In-orbit Radiation Damage Characterization of SiPMs in the GRID-02 CubeSat Detector
- A compact instrument for gamma-ray burst detection on a CubeSat platform II: Detailed design, assembly and validation
- Temperature dependence of radiation damage annealing of Silicon Photomultipliers
- Characterization of SiPM Performance in a Small Satellite in Low Earth Orbit using LabOSat-01
- The design and performance of CUBES -- a CubeSat X-ray detector
- Real-time Likelihood Methods for Improved Gamma-ray Transient Detection and Localization
- Gamma-Ray Burst Polarimetry with the COMCUBE-S CubeSat Swarm -- Design and Performance Simulations
- Characterization of more than three years of in-orbit radiation damage of SiPMs on GRBAlpha and VZLUSAT-2 CubeSats