Radiation Damage Study of SensL J-Series Silicon Photomultipliers Using 101.4 MeV Protons
arXiv:2007.10919 · doi:10.1016/j.nima.2020.164203
Abstract
Radiation damage of J-series silicon photomultipliers (SiPMs) has been studied in the context of using these photodetectors in future space-borne scintillation detectors. Several SiPM samples were exposed to 101.4 MeV protons, with 1 MeV neutron equivalent fluence ranging from 1.27*10^8 n/cm^2 to 1.23*10^10 n/cm^2 . After the irradiation, the SiPMs experienced a large increase in the dark current and noise, which may pose problems for long-running space missions in terms of power consumption, thermal control and detection of low-energy events. Measurements performed with a CeBr3 scintillator crystal showed that after exposure to 1.23*10^10 n/cm^2 and following room-temperature annealing, the dark noise of a single 6 mm square SiPM at room temperature increased from 0.1 keV to 2 keV. Because of the large SiPM noise, the gamma-ray detection threshold increased to approximately 20 keV for a CeBr3 detector using a 4-SiPM array and 40 keV for a detector using a 16-SiPM array. Only a small effect of the proton irradiation on the average detector signal was observed, suggesting no or little change to the SiPM gain and photon detection efficiency.
Published in Nuclear Instruments and Methods in Physics Research Section A
References in corpus (6)
- Radiation Hardness Tests of SiPMs for the JLab Hall D Barrel Calorimeter
- Radiation Damage Studies of Silicon Photomultipliers
- Localisation of gamma-ray interaction points in thick monolithic CeBr3 and LaBr3:Ce scintillators
- Silicon Photo-Multiplier radiation hardness tests with a beam controlled neutron source
- Influence of X-ray Irradiation on the Properties of the Hamamatsu Silicon Photomultiplier S10362-11-050C
- The MERger-event Gamma-Ray (MERGR) Telescope
Cited by in corpus (6)
- Radiation damage assessment of SensL SiPMs
- In-orbit Radiation Damage Characterization of SiPMs in the GRID-02 CubeSat Detector
- A compact instrument for gamma-ray burst detection on a CubeSat platform I: Design drivers and expected performance
- A compact instrument for gamma-ray burst detection on a CubeSat platform II: Detailed design, assembly and validation
- CubeSats for Gamma-Ray Astronomy
- Gamma-Ray Burst Polarimetry with the COMCUBE-S CubeSat Swarm -- Design and Performance Simulations