Rotation sensing with improved stability using point source atom interferometry
arXiv:2002.08369 · doi:10.1103/PhysRevA.102.013326
Abstract
Point source atom interferometry is a promising approach for implementing robust, high-sensitivity, rotation sensors using cold atoms. However, its scale factor, i.e., the ratio between the interferometer signal and the actual rotation rate, depends on the initial conditions of the atomic cloud, which may drift in time and result in bias instability, particularly in compact devices with short interrogation times. We present two methods to stabilize the scale factor, one relying on a model-based correction which exploits correlations between multiple features of the interferometer output and works on a single-shot basis, and the other a self-calibrating method where a known bias rotation is applied to every other measurement, requiring no prior knowledge of the underlying model but reducing the sensor bandwidth by a factor of two. We demonstrate both schemes experimentally with complete suppression of scale factor drifts, maintaining the original rotation sensitivity and allowing for bias-free operation over several hours.
C.A. and D.Y. contributed equally. The text consists of 6 pages, 6 figures
References in corpus (25)
- Measurement of the fine-structure constant as a test of the Standard Model
- Precision Measurement of the Newtonian Gravitational Constant Using Cold Atoms
- New determination of the fine structure constant and test of the quantum electrodynamics
- Multi-axis inertial sensing with long-time point source atom interferometry
- Gravity measurements below with a transportable absolute quantum gravimeter
- 6-axis inertial sensor using cold-atom interferometry
- Testing General Relativity with Atom Interferometry
- Space-borne Bose-Einstein condensation for precision interferometry
- Test of Equivalence Principle at Level by a Dual-species Double-diffraction Raman Atom Interferometer
- Long-Term Stability of an Area-Reversible Atom-Interferometer Sagnac Gyroscope
- Mobile quantum gravity sensor with unprecedented stability
- Gravity surveys using a mobile atom interferometer
- Interleaved Atom Interferometry for High Sensitivity Inertial Measurements
- Dual Matter-Wave Inertial Sensors in Weightlessness
- Characterization and limits of a cold atom Sagnac interferometer
- Absolute airborne gravimetry with a cold atom sensor
- Navigation-compatible hybrid quantum accelerometer using a Kalman filter
- The Sagnac effect: 20 years of development in matter-wave interferometry
- Enhanced atom interferometer readout through the application of phase shear
- Improving the accuracy of atom interferometers with ultracold sources
- The effect of wavefront aberrations in atom interferometry
- Development of compact cold-atom sensors for inertial navigation
- Multi-axis atom interferometer gyroscope with a single source of atoms
- Composite-fringe atom interferometry for high dynamic-range sensing
- Multiport Atom Interferometry for Inertial Sensing
Cited by in corpus (9)
- High-accuracy inertial measurements with cold-atom sensors
- A continuous, sub-Doppler-cooled atomic beam interferometer for inertial sensing
- Atom interferometry with thousand-fold increase in dynamic range
- Robust inertial sensing with point-source atom interferometry for interferograms spanning a partial period
- Losses of thulium atoms from optical dipole traps operating at 532 and 1064 nm
- Closed-loop measurements in an atom interferometer gyroscope with velocity-dependent phase-dispersion compensation
- Analyzing the sensitivity of an atom interferometer with a phase-modulation readout scheme
- Sensitivity and Bandwidth of a Point-Source-Interferometry-based Inertial Measurement Unit Employing Large Momentum Transfer and Launched Atoms
- High sensitivity multi-axes rotation sensing using large momentum transfer point source atom interferometry