Improving the accuracy of atom interferometers with ultracold sources
arXiv:1804.04909 · doi:10.1088/1367-2630/aaf07d
Abstract
We report on the implementation of ultracold atoms as a source in a state of the art atom gravimeter. We perform gravity measurements with 10 nm/s 2 statistical uncertainties in a so-far unexplored temperature range for such a high accuracy sensor, down to 50 nK. This allows for an improved characterization of the most limiting systematic effect, related to wavefront aberrations of light beam splitters. A thorough model of the impact of this effect onto the measurement is developed and a method is proposed to correct for this bias based on the extrapolation of the measurements down to zero temperature. Finally, an uncertainty of 13 nm/s 2 is obtained in the evaluation of this systematic effect, which can be improved further by performing measurements at even lower temperatures. Our results clearly demonstrate the benefit brought by ultracold atoms to the metrological study of free falling atom interferometers. By tackling their main limitation, our method allows reaching record-breaking accuracies for inertial sensors based on atom interferometry.
References in corpus (29)
- Precision Measurement of the Newtonian Gravitational Constant Using Cold Atoms
- New determination of the fine structure constant and test of the quantum electrodynamics
- Interferometry with Bose-Einstein Condensates in Microgravity
- Multi-axis inertial sensing with long-time point source atom interferometry
- Gravity measurements below with a transportable absolute quantum gravimeter
- Atom Interferometry tests of the isotropy of post-Newtonian gravity
- Continuous Cold-atom Inertial Sensor with Rotation Stability
- Limits to the sensitivity of a low noise compact atomic gravimeter
- Phase shift in atom interferometry due to spacetime curvature
- Mobile quantum gravity sensor with unprecedented stability
- Effect of cold collisions on spin coherence and resonance shifts in a magnetically trapped ultra-cold gas
- Matter wave lensing to picokelvin temperatures
- Quantum Tests of the Einstein Equivalence Principle with the STE-QUEST Space Mission
- Stability comparison of two absolute gravimeters: optical versus atomic interferometers
- Why momentum width matters for atom interferometry with Bragg pulses
- Cold atom gravimetry with a Bose-Einstein Condensate
- Enhanced atom interferometer readout through the application of phase shear
- 80hk Momentum Separation with Bloch Oscillations in an Optically Guided Atom Interferometer
- A spaceborne gravity gradiometer concept based on cold atom interferometers for measuring Earth's gravity field
- Atom interferometry in an optical cavity
- The effect of wavefront aberrations in atom interferometry
- High-resolution atom interferometers with suppressed diffraction phases
- Observation of Extra Photon Recoil in a Distorted Optical Field
- Active Control of Laser Wavefronts in Atom Interferometers
- Controlling the Multiport Nature of Bragg Diffraction in Atom Interferometry
- The Role of Source Coherence in Atom Interferometery
- Light-shift tomography in an optical-dipole trap for neutral atoms
- Effective velocity distribution in an atom gravimeter: effect of the convolution with the response of the detection
- Light shifts in atomic Bragg diffraction
Cited by in corpus (37)
- Interleaved Atom Interferometry for High Sensitivity Inertial Measurements
- High-accuracy inertial measurements with cold-atom sensors
- Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100)
- Concept study and preliminary design of a cold atom interferometer for space gravity gradiometry
- High Precision, Quantum-Enhanced Gravimetry with a Bose-Einstein Condensate
- Improving cold-atom sensors with quantum entanglement: Prospects and challenges
- Airborne absolute gravimetry with a quantum sensor, comparison with classical technologies
- Gravity Field Mapping Using Laser Coupled Quantum Accelerometers in Space
- Optimal control of the transport of Bose-Einstein condensates with atom chips
- Simultaneous accurate determination of both gravity and its vertical gradient
- Multi-loop atomic Sagnac interferometry
- Precision inertial sensing with quantum gases
- Testing the Universality of Free Fall using correlated K -- Rb interferometers
- Rotation sensing with improved stability using point source atom interferometry
- Coupling Quantum Matter and Gravity
- Gravity field modelling for the Hannover 10m atom interferometer
- Calibration of a superconducting gravimeter with an absolute atom gravimeter
- Accurate trajectory alignment in cold-atom interferometers with separated laser beams
- All-Optical Matter-Wave Lens using Time-Averaged Potentials
- Dark matter searches using accelerometer-based networks
- Atomic gravimeter robust to environmental effects
- Precision measurements with cold atoms and trapped ions
- A prototype industrial laser system for cold atom inertial sensing in space
- Low noise phase-locked laser system for atom interferometry
- Impact of direct digital synthesizer finite resolution on atom gravimeters
- Limitations for field-enhanced atom interferometry
- Atom interferometry using - Raman transitions between and
- Measuring the gravitational acceleration with precision matter-wave velocimetry
- Separating the output ports of a Bragg interferometer via velocity selective transport
- Matter waves and clocks do not observe uniform gravitational fields
- Cold Atoms in Space: Community Workshop Summary and Proposed Road-Map
- Dual Open Atom Interferometry for Compact and Mobile Quantum Sensing
- A two-state Kalman estimator for atomic gravimetry
- High-contrast double Bragg interferometry via detuning control
- Hybrid electrostatic-atomic accelerometer for future space gravity missions
- Wavefront Mapping for Absolute Atom Interferometry
- Delta-kick Squeezing