Calibrating GONG Magnetograms with End-to-end Instrument Simulation II: Theory of Calibration
arXiv:2002.02490 · doi:10.1007/s11207-020-01709-w
Abstract
This is the second of three papers describing an `absolute' calibration of the GONG magnetograph using an end-to-end simulation of its measurement process. In the first paper, we described the GONG instrument and our `end-to-end' simulation of its measurement process. In this paper, we consider the theory of calibration, and magnetograph comparison in general, identifying some of the significant issues and pitfalls. The calibration of a magnetograph is a function of whether or not it preserves flux, independent of its spatial resolution. However, we find that the one-dimensional comparison methods most often used for magnetograph calibration and comparison will show dramatic differences between two magnetograms with differing spatial resolution, even if they both preserve flux. Some of the apparent disagreement between magnetograms found in the literature are likely a result of these instrumental resolution differences rather than any intrinsic calibration differences. To avoid them, spatial resolution must be carefully matched prior to comparing magnetograms or making calibration curves. In the third paper, we apply the lessons learned here to absolute calibration of GONG using our `end-to-end' measurement simulation.
arXiv commentSubmitted to Solar Physics, second of three papers (the other two are arXiv submissions 3034511 and 3034660)
References in corpus (11)
- Ensemble modeling of CMEs using the WSA-ENLIL+Cone model
- The Open Flux Problem
- On the Formation Height of the SDO/HMI Fe 6173 Doppler Signal
- Solar magnetic activity cycles, coronal potential field models and eruption rates
- Numerical simulations of sunspot decay: On the penumbra -- Evershed flow -- moat flow connection
- Comparison of Ground- and Space-based Longitudinal Magnetograms
- Convective blueshifts in the solar atmosphere, I. Absolute measurements with LARS of the spectral lines at 6302 Å
- Using Realistic MHD Simulations for Modeling and Interpretation of Quiet-Sun Observations with the Solar Dynamics Observatory Helioseismic and Magnetic Imager
- Calibrating GONG Magnetograms with End-to-end Instrument Simulation III: Comparison, Calibration, and Results
- Calibrating GONG Magnetograms with End-to-end Instrument Simulation I: Background, the GONG Instrument, and End-to-end Simulation
- Calibrating GONG Magnetograms with End-to-end Instrument Simulation II: Theory of Calibration
Cited by in corpus (6)
- Magnetograph Saturation and the Open Flux Problem
- Calibrating GONG Magnetograms with End-to-end Instrument Simulation III: Comparison, Calibration, and Results
- Magnetograms underestimate even unipolar magnetic flux nearly everywhere on the solar disk
- Limitations and biases in the retrieval of the polar magnetic field I: the role of the magnetic filling factor in Milne-Eddington inversions of simulated Hinode/SP data
- Calibrating GONG Magnetograms with End-to-end Instrument Simulation I: Background, the GONG Instrument, and End-to-end Simulation
- Calibrating GONG Magnetograms with End-to-end Instrument Simulation II: Theory of Calibration