Refractive index sensing with temperature compensation by a multimode-interference fiber-based optical frequency comb sensing cavity
arXiv:1905.04901 · doi:10.1364/OE.27.021463
Abstract
We proposed a refractive index (RI) sensing method with temperature compensation by using an optical frequency comb (OFC) sensing cavity employing a multimode-interference (MMI) fiber, namely, the MMI-OFC sensing cavity. The MMI-OFC sensing cavity enables simultaneous measurement of material-dependent RI and sample temperature by decoding from the comb spacing frequency shift and the wavelength shift of the OFC. We realized the simultaneous and continuous measurement of RI-related concentration of a liquid sample and its temperature with precisions of 1.6*10^-4 RIU and 0.08 degree. The proposed method would be a useful means for the various applications based on RI sensing.
22 pages
References in corpus (5)
- Coherent Raman spectro-imaging with laser frequency combs
- Scan-less confocal phase microscopy based on dual comb spectroscopy of two-dimensional-image-encoding optical frequency comb
- Dual-optical-comb spectroscopic ellipsometry
- Scan-less hyperspectral dual-comb single-pixel-imaging in both amplitude and phase
- Refractive-index-sensing radio-frequency comb with intracavity multi-mode interference fibre sensor