Development of an "-ToF" detector for correlated measurement of atomic masses and decay properties
arXiv:1904.11589 · doi:10.1016/j.nima.2019.163198
Abstract
We have developed a novel detector, referred to as an "-ToF detector", for correlated measurements of atomic masses and decay properties of low-yield, short-lived radioactive isotopes using a multi-reflection time-of-flight mass spectrograph. By correlating measured time-of-flight signals with decay events, it will be possible to suppress background events and obtain accurate, high-precision mass values even in cases of very low event rates. An offline test of the -ToF detector has shown that the time-of-flight detection efficiency for 5.48~MeV -rays is more than 90\% and yields a time resolution of 251.5(68)~ps and an energy resolution of 141.1(9)~keV. Using a two-dimensional spectrum of the correlated -ray energy and time-of-flight, the -rays from mixed sources could be fairly well resolved.
6pages, 10 figures