Abstract
The masses of the exotic isotopes Ac and Ra have been measured with a multi-reflection time-of-flight mass spectrograph. These isotopes were obtained in flight as fusion-evaporation products behind the gas-filled recoil ion separator GARIS-II at RIKEN. The new direct mass measurements serve as an independent and direct benchmark for existing - spectroscopy data in this mass region. Further, new mass anchor points are set for U and Np nuclei close to the shell closure for a future benchmark of the sub-shell for neutron-deficient heavy isotopes. Our mass results are in general in good agreement with the previously indirectly-determined mass values. Together with the measurement data, reasons for possible mass ambiguities from decay-data links between ground states are discussed.
References in corpus (7)
- First direct mass measurements of nuclides around with a Multireflection Time-of-Flight Mass Spectrograph
- Single-reference high-precision mass measurement with a multi-reflection time-of-flight mass spectrograph
- Alpha Decay in the Complex Energy Shell Model
- First Online Mass Measurements of Isobar Chains via Multi-Reflection Time-of-Flight Mass Spectrograph Coupled with GARIS-II
- Wide-band mass measurements with a multi-reflection time-of-flight mass spectrograph
- Study of the long-lived excited state in the neutron deficient nuclides Po by precision mass measurement
- Corrections of alpha- and proton-decay energies in implantation experiments
Cited by in corpus (7)
- High-resolution, accurate MR-TOF-MS for short-lived, exotic nuclei of few events in their ground and low-lying isomeric states
- Improving wide-band mass measurements in a multi-reflection time-of-flight mass spectrograph by usage of a concomitant measurement scheme
- Atomic masses of intermediate-mass neutron-deficient nuclei with relative uncertainty down to 35-ppb via multireflection time-of-flight mass spectrograph
- Development of an "-ToF" detector for correlated measurement of atomic masses and decay properties
- A new beamline for Resonant Excitation of Beams with Electromagnetic fields and Lasers (REBEL) and Stopping and Trapping of Radioactive Isotopes for Precision Experiments (STRIPE)
- Reduction of contaminants originating from primary beam by improving the beam stoppers in GARIS-II
- First high-precision direct determination of the atomic mass of a superheavy nuclide