activity
20042026
most citedThe Cosmic Ray Muon Flux at WIPP

40 citations · 141 across the 7 of their papers we have counts for

collaborators

7 papers

nucl-ex2026

High-Precision Mass Measurements of Proton-Rich Rh, Pd, Cd isotopes in the vicinity of 100Sn and Impact on X-Ray Burst and Supernova Nucleosynthesis

D. S. Hou, W. D. Xian, M. Rosenbusch +55

Using the ZeroDegree multi-reflection time-of-flight mass spectrograph of the CRISMASS project at RIKEN Radioactive Isotope Beam Factory, we performed high-precision mass measureme…

physics.ins-det2019★ 15 cited

Development of an "-ToF" detector for correlated measurement of atomic masses and decay properties

T. Niwase, M. Wada, P. Schury +12

We have developed a novel detector, referred to as an "-ToF detector", for correlated measurements of atomic masses and decay properties of low-yield, short-lived radioactive is…

physics.ins-det2019★ 6 cited

High-stability, high-voltage power supplies for use with multi-reflection time-of-flight mass spectrographs

P. Schury, M. Wada, H. Wollnik J-Y. Moon +2

Achieving the highest possible mass resolving power in a multi-reflection time-of-flight mass spectrometer requires very high-stability power supplies. To this end, we have develop…

nucl-ex2013★ 29 cited

Wide-band mass measurements with a multi-reflection time-of-flight mass spectrograph

P. Schury, Y. Ito, M. Wada +1

We characterize the mass bandwidth of the a multi-reflection time-of-flight mass spectrograph, showing both the functional and useful mass bandwidth. We then demonstrate the use of…

physics.ins-det2013★ 32 cited

A novel ion cooling trap for multi-reflection time-of-flight mass spectrograph

Y. Ito, P. Schury, M. Wada +8

A radiofrequency quadrupole ion trap system for use with a multi-reflection time-of-flight mass spectrograph (MRTOF) for short-lived nuclei has been developed. The trap system cons…

nucl-ex2012★ 19 cited

An rf-carpet electrospray ion source to provide isobaric mass calibrants for trans-uranium elements

S. Naimi, S. Nakamura, Y. Ito +8

For trans-uranium elements, stable atomic isobars do not exist. In order to provide isobaric reference ions for the mass measurement of trans-uranium elements, an electrospray ion…

astro-ph2004★ 40 cited

The Cosmic Ray Muon Flux at WIPP

E. -I. Esch, T. J. Bowles, A. Hime +3

In this work a measurement of the muon intensity at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, NM, USA is presented. WIPP is a salt mine with a depth of 655 m. The verti…