Galactic axions search with a superconducting resonant cavity
arXiv:1903.06547 · doi:10.1103/PhysRevD.99.101101
Abstract
To account for the dark matter content in our Universe, post-inflationary scenarios predict for the QCD axion a mass in the range $(10-10^3)\,μ\mbox{eV}$. Searches with haloscope experiments in this mass range require the monitoring of resonant cavity modes with frequency above 5\,GHz, where several experimental limitations occur due to linear amplifiers, small volumes, and low quality factors of Cu resonant cavities. In this paper we deal with the last issue, presenting the result of a search for galactic axions using a haloscope based on a $36\,\mbox{cm}^3$ NbTi superconducting cavity. The cavity worked at $T=4\,\mbox{K}$ in a 2\,T magnetic field and exhibited a quality factor for the TM010 mode at 9\,GHz. With such values of the axion signal is significantly increased with respect to copper cavity haloscopes. Operating this setup we set the limit $g_{aγγ}<1.03\times10^{-12}\,\mbox{GeV}^{-1}$ on the axion photon coupling for a mass of about 37\,eV. A comprehensive study of the NbTi cavity at different magnetic fields, temperatures, and frequencies is also presented.
References in corpus (18)
- Fano resonances in nanoscale structures
- New CAST Limit on the Axion-Photon Interaction
- A SQUID-based microwave cavity search for dark-matter axions
- New ALPS Results on Hidden-Sector Lightweights
- First results from a microwave cavity axion search at 24 micro-eV
- The ORGAN Experiment: An axion haloscope above 15 GHz
- New Exclusion Limits for the Search of Scalar and Pseudoscalar Axion-Like Particles from "Light Shining Through a Wall"
- Redefining the Axion Window
- The PVLAS experiment: measuring vacuum magnetic birefringence and dichroism with a birefringent Fabry-Perot cavity
- Searching for galactic axions through magnetized media: the QUAX proposal
- Analysis of single-photon and linear amplifier detectors for microwave cavity dark matter axion searches
- Reliable determination of vortex parameters from measurements of the microwave complex resistivity
- Design and Operational Experience of a Microwave Cavity Axion Detector for the 20-100 micro-eV Range
- Concept of multiple-cell cavity for axion dark matter search
- Operation of a ferromagnetic axion haloscope at eV
- New solar axion search in CAST with He filling
- The KLASH Proposal
- The Klash Proposal: Status and Perspectives
Cited by in corpus (98)
- Invisible Axion Search Methods
- Feebly-Interacting Particles:FIPs 2020 Workshop Report
- Axion Dark Matter Search around 6.7 eV
- First Results from Axion Haloscope at CAPP around 10.7 eV
- Axion search with a quantum-limited ferromagnetic haloscope
- Search for axion-like dark matter with ferromagnets
- Search for invisible axion dark matter of mass meV with the QUAX-- experiment
- Search for invisible axion dark matter with a multiple-cell haloscope
- Broadband solenoidal haloscope for terahertz axion detection
- Axion Quasiparticles for Axion Dark Matter Detection
- Bounds on axion-like particles from the diffuse supernova flux
- Cornering the axion with CP-violating interactions
- Effective Field Theory of Dark Matter Direct Detection With Collective Excitations
- Revisiting the detection rate for axion haloscopes
- Search for galactic axions with a high-Q dielectric cavity
- Axion Dark Matter eXperiment: Detailed Design and Operations
- Direct detection of dark photon dark matter using radio telescopes
- ALP Dark Matter in a Primordial Black Hole Dominated Universe
- Simulations of axion-like particles in the post-inflationary scenario
- Search for galactic axions with a traveling wave parametric amplifier
- Gravitational waves from axion-like particle cosmic string-wall networks
- Dark Matter Targets for Axion-like Particle Searches
- The Canfranc Axion Detection Experiment (CADEx): Search for axions at 90 GHz with Kinetic Inductance Detectors
- On the Wondrous Stability of ALP Dark Matter
- Axion helioscopes as solar magnetometers
- Superconducting detectors for rare event searches in experimental astroparticle physics
- The future search for low-frequency axions and new physics with the FLASH resonant cavity experiment at Frascati National Laboratories
- Search for Axion dark matter with the QUAX-LNF tunable haloscope
- Direct Detection of Dark Matter -- APPEC Committee Report
- Searching for Time-Dependent Axion Dark Matter Signals in Pulsars
- Cavity Detection of Gravitational Waves: Where Do We Stand?
- Coherent coupling between multiple ferrimagnetic spheres and a microwave cavity in the quantum-limit
- Quantum Science and the Search for Axion Dark Matter
- Axion minivoids and implications for direct detection
- Realization of a high quality factor resonator with hollow dielectric cylinders for axion searches
- Modifying PyUltraLight to model scalar dark matter with self-interactions
- Dark Matter Axion Search with HAYSTAC Phase II
- Axion Dark Matter eXperiment around 3.3 μeV with Dine-Fischler-Srednicki-Zhitnitsky Discovery Ability
- Extended Axion Dark Matter Search Using the CAPP18T Haloscope
- Axion Haloscope Using an 18 T High Temperature Superconducting Magnet
- An improved analysis framework for axion dark matter searches
- Axion-Photon Conversion in 3D Media and Astrophysical Plasmas
- Discovery prospects with the Dark-photons & Axion-Like particles Interferometer
- Microwave measurements of the high magnetic field vortex motion pinning parameters in NbSn
- RADES axion search results with a High-Temperature Superconducting cavity in an 11.7 T magnet
- Near-quantum-limited axion dark matter search with the ORGAN experiment around 26 eV
- Limits on Dark Photons, Scalars, and Axion-Electromagnetodynamics with The ORGAN Experiment
- A dark matter telescope probing the 6 to 60 GHz band
- ALP Searches at the LHC: FASER as a Light Shining through Walls Experiment
- Rydberg-atom-based single-photon detection for haloscope axion searches
- High-quality axions in solutions to the problem
- Detector Array Readout with Traveling Wave Amplifiers
- Warm and Fuzzy Dark Matter: Free Streaming of Wave Dark Matter
- DFSZ-Type Axions and Where to Find Them
- The axion dark matter echo: a detailed analysis
- Axion Echos from the Supernova Graveyard
- High quality factor photonic cavity for dark matter axion searches
- Dark Matter Axions, Non-Newtonian Gravity and Constraints on them from Recent Measurement of the Casimir Force in the Micrometer Separation Range
- Phenomenology of the companion-axion model: photon couplings
- Solar radio emissions and ultralight dark matter
- First Axion-Like Particle Results from a Broadband Search for Wave-Like Dark Matter in the 44 to 52 eV Range with a Coaxial Dish Antenna
- S.M.A.S.H.E.D.: Standard Model Axion Seesaw Higgs Inflation Extended for Dirac Neutrinos
- NuSTAR as an Axion Helioscope
- Surface impedance measurements in superconductors in dc magnetic fields: challenges and relevance to particle physics experiments
- A method based on a dual frequency resonator to estimate physical parameters of superconductors from surface impedance measurements in a magnetic field
- Impact of the superconductors properties on the measurement sensitivity of resonant-based axion detectors
- Taiwan Axion Search Experiment with Haloscope: CD102 Analysis Details
- Development of a cavity with photonic crystal structure for axion searches
- New Technologies for Axion and Dark Photon Searches
- A forecast of the sensitivity of the DALI Experiment to Galactic axion dark matter
- Search for vector dark matter in microwave cavities with Rydberg atoms
- Imperfect Axion Precludes the Domain Wall Problem
- DALI sensitivity to streaming axion dark matter
- Catalogues of Cosmologically Self-Consistent Hadronic QCD Axion Models
- Search for an interaction mediated by axion-like particles with ultracold neutrons at the PSI
- Ultimate light-shining-through-a-wall experiments to establish QCD axions as the dominant form of dark matter
- Horn-array haloscope for volume-efficient broadband axion searches
- Axion signals from neutron star populations
- Quantum-enhanced dark matter detection with in-cavity control: mitigating the Rayleigh curse
- Axion detection via superfluid He ferromagnetic phase and quantum measurement techniques
- Analytical considerations for optimal axion haloscope design
- Microwave Hall measurements using a circularly polarized dielectric cavity
- First results of the CAST-RADES haloscope search for axions at 34.67 eV
- Berry phase in axion physics, SM global structure, and generalized symmetries
- ALP Dark Matter from Kinetic Fragmentation: Opening up the Parameter Window
- Search for post-inflationary QCD axions with a quantum-limited tunable microwave receiver
- Advancing Globular Cluster Constraints on the Axion-Photon Coupling
- Cavity, lumped-circuit, and spin-based detection of axion dark matter: differences and similarities
- On the possibility of mixed axion/neutralino dark matter in specific SUSY DFSZ axion models
- The radiation emitted from axion dark matter in a homogeneous magnetic field, and possibilities for detection
- An introduction to axions and their detection
- Resonant enhancement of axion dark matter decay
- Retuning radio astronomy for axion dark matter with neutron stars
- CAPP-8TB: Axion Dark Matter Search Experiment around 6.7 eV
- Multi-mode Analysis of Surface Losses in a Superconducting Microwave Resonator in High Magnetic Fields
- Extended Haloscope Search and Exclusion of a Candidate Signal near 1.036 GHz
- Spiral Tuning of Wire-metamaterial Cavity for Plasma Haloscope
- Microwave Vortex Motion Characterization of NbSn Coatings for Applications in High Magnetic Fields