Axion detection via superfluid He ferromagnetic phase and quantum measurement techniques
arXiv:2309.09160 · doi:10.1007/JHEP09(2024)191
Abstract
We propose to use the nuclear spin excitation in the ferromagnetic A1 phase of the superfluid He for the axion dark matter detection. This approach is striking in that it is sensitive to the axion-nucleon coupling, one of the most important features of the QCD axion introduced to solve the strong CP problem. We review a quantum mechanical description of the nuclear spin excitation and apply it to the estimation of the axion-induced spin excitation rate. We also describe a possible detection method of the spin excitation in detail and show that the combination of the squeezing of the final state with the Josephson parametric amplifier and the homodyne measurement can enhance the sensitivity. It turns out that this approach gives good sensitivity to the axion dark matter with the mass of depending on the size of the external magnetic field. We estimate the parameters of experimental setups, e.g., the detector volume and the amplitude of squeezing, required to reach the QCD axion parameter space.
v3: 41 pages, 7 figures, accepted version for JHEP, estimated sensitivity has been improved
References in corpus (52)
- Circuit Quantum Electrodynamics
- Introduction to Quantum Noise, Measurement and Amplification
- Strongly coupled magnons and cavity microwave photons
- Hybridizing ferromagnetic magnons and microwave photons in the quantum limit
- Spinor Bose-Einstein condensates
- Detection of 15 dB Squeezed States of Light and their Application for the Absolute Calibration of Photoelectric Quantum Efficiency
- A SQUID-based microwave cavity search for dark-matter axions
- A Search for Invisible Axion Dark Matter with the Axion Dark Matter Experiment
- A quantum-enhanced search for dark matter axions
- Results from phase 1 of the HAYSTAC microwave cavity axion experiment
- The ORGAN Experiment: An axion haloscope above 15 GHz
- Unified Description of Nambu-Goldstone Bosons without Lorentz Invariance
- Improved axion emissivity from a supernova via nucleon-nucleon bremsstrahlung
- Axion Dark Matter Search around 6.7 eV
- Revealing the Dark Matter Halo with Axion Direct Detection
- Searching for Dark Matter with a Superconducting Qubit
- Quantum magnonics: magnon meets superconducting qubit
- Galactic axions search with a superconducting resonant cavity
- Counting rule for Nambu-Goldstone modes in nonrelativistic systems
- Search for axionlike dark matter with a liquid-state nuclear spin comagnetometer
- Search for invisible axion dark matter with a multiple-cell haloscope
- Constraints on bosonic dark matter from ultralow-field nuclear magnetic resonance
- Topological Susceptibility and QCD Axion Mass: QED and NNLO corrections
- Analysis of single-photon and linear amplifier detectors for microwave cavity dark matter axion searches
- First demonstration of 6 dB quantum noise reduction in a kilometer scale gravitational wave observatory
- Fabrication of low-loss quasi-single-mode PPLN waveguide and its application to a modularized broadband high-level squeezer
- Constraints on Axion-like Particles and Nucleon Pairing in Dense Matter from the Hot Neutron Star in HESS J1731-347
- Direct Search for Dark Matter Axions Excluding ALP Cogenesis in the 63-67 micro-eV Range, with The ORGAN Experiment
- Searching for Invisible Axion Dark Matter with an 18T Magnet Haloscope
- Axion-like Relics: New Constraints from Old Comagnetometer Data
- NASDUCK: New Constraints on Axion-like Dark Matter from Floquet Quantum Detector
- Squeezed vacuum used to accelerate the search for a weak classical signal
- Exploring Two Higgs Doublet Models Through Higgs Production
- Over-8-dB squeezed light generation by a broadband waveguide optical parametric amplifier toward fault-tolerant ultra-fast quantum computers
- Search for galactic axions with a high-Q dielectric cavity
- Detecting Light Boson Dark Matter through Conversion into Magnon
- Storage Ring Probes of Dark Matter and Dark Energy
- Near-Quantum-Noise Axion Dark Matter Search at CAPP around 9.5 eV
- Direct measurement of the He magnetic moments
- Laboratory Constraints on the Neutron-Spin Coupling of feV-scale Axions
- Dissipative stabilization of squeezing beyond 3 dB in a microwave mode
- Strong Coupling Corrections to the Ginzburg-Landau Theory of Superfluid ^{3}He
- Ultimate precision limit of noise sensing and dark matter search
- Quantum Science and the Search for Axion Dark Matter
- Axion search with quantum nondemolition detection of magnons
- On the Sensitivity of Spin-Precession Axion Experiments
- Generation and measurement of a squeezed vacuum up to 100 MHz at 1550 nm with a semi-monolithic optical parametric oscillator designed towards direct coupling with waveguide modules
- Recent direct measurement of the Top quark mass and quasi-infrared fixed point
- Axion wind detection with the homogeneous precession domain of superfluid helium-3
- Flux-driven Josephson parametric amplifier for sub-GHz frequencies fabricated with side-wall passivated spacer junction technology
- Dark matter detection using nuclear magnetization in magnet with hyperfine interaction
- Towards an electrostatic storage ring for fundamental physics measurements