Characterisation of a large area silicon photomultiplier
arXiv:1810.02275 · doi:10.1016/j.nima.2019.162796
Abstract
This work illustrates and compares some methods to measure the most relevant parameters of silicon photo-multipliers (\sipm{}s), such as photon detection efficiency as a function of over-voltage and wavelength, dark count rate, optical cross-talk, afterpulse probability. For the measurement of the breakdown voltage, , several methods using the current-voltage curve are compared, such as the "IV Model", the "relative logarithmic derivative", the "inverse logarithmic derivative", the "second logarithmic derivative", and the "third derivative" models. We also show how some of these characteristics can be quite well described by few parameters and allow, for example, to build a function of the wavelength and over-voltage describing the photodetection efficiency. This is fundamental to determine the working point of SiPMs in applications where external factors can affect it. These methods are applied to the large area monolithic hexagonal SiPM S10943-2832(X), developed in collaboration with Hamamatsu and adopted for a camera for a gamma-ray telescope, called the SST-1M. We describe the measurements of the performance at room temperature of this device. The methods used here can be applied to any other device and the physics background discussed here are quite general and valid for a large phase-space of the parameters.
References in corpus (11)
- Characterisation Studies of Silicon Photomultipliers
- Design and Operation of FACT -- The First G-APD Cherenkov Telescope
- Characterization of Three High Efficiency and Blue Sensitive Silicon Photomultipliers
- An innovative silicon photomultiplier digitizing camera for gamma-ray astronomy
- On the characterisation of SiPMs from pulse-height spectra
- Design, optimization and characterization of the light concentrators of the single-mirror small size telescopes of the Cherenkov Telescope Array
- A model based DC analysis of SiPM breakdown voltages
- SiPMs characterization and selection for the DUNE far detector photon detection system
- SENSE: A comparison of photon detection efficiency and optical crosstalk of various SiPM devices
- Correcting for accidental correlations in saturated avalanche photodiodes
- Silicon Photomultiplier for Medical Imaging -Analysis of SiPM characteristics-
Cited by in corpus (15)
- Construction and On-site Performance of the LHAASO WFCTA Camera
- SiPM cross-talk in liquid argon detectors
- Large-Area SiPM Pixels (LASiPs): a cost-effective solution towards compact large SPECT cameras
- Large scale characterization and calibration strategy of a SiPM-based camera for gamma-ray astronomy
- SiPM behaviour under continuous light
- The SST-1M imaging atmospheric Cherenkov telescope for gamma-ray astrophysics
- Silicon photomultiplers in Very High Energy gamma-ray astrophysics
- First observation of neutral bremsstrahlung electroluminescence in liquid argon
- Batch VUV4 Characterization for the SBC-LAr10 scintillating bubble chamber
- Properties of large SiPM at room temperature
- Performance and radiation damage mitigation strategy for silicon photomultipliers on LEO space missions
- Analysis of commissioning data from SST-1M : A Prototype of Single-Mirror Small Size Telescope
- Characterisation of the MUSIC ASIC for large-area silicon photomultipliers for gamma-ray astronomy
- A Mini-Imaging Air Cherenkov Telescope
- Characterisation of SiPM Photon Emission in the Dark