On the characterisation of SiPMs from pulse-height spectra
arXiv:1609.01181 · doi:10.1016/j.nima.2017.02.049
Abstract
Methods are developed, which use the pulse-height spectra of SiPMs measured in the dark and illuminated by pulsed light, to determine the pulse shape, the dark-count rate, the gain, the average number of photons initiating a Geiger discharge, the probabilities for prompt cross-talk and after-pulses, as well as the electronics noise and the gain fluctuations between and in pixels. The entire pulse-height spectra, including the background regions in-between the peaks corresponding to different number of Geiger discharges, are described by single functions. As a demonstration, the model is used to characterise a KETEK SiPM with 4382 pixels of 15 μm x 15 μm area for voltages between 2.5 and 8 V above the breakdown voltage at 20°C. The results are compared to other methods of characterising SiPMs. Finally, examples are given, how the complete description of the pulse-eight spectra can be used to optimise the operating voltage of SiPMs, and a method for an in-situ calibration and monitoring of SiPMs, suited for large-scale applications, is proposed.
arXiv comment18 pages 11 figures 2 appendices
References in corpus (6)
- Characterisation Studies of Silicon Photomultipliers
- Analytical models of probability distribution and excess noise factor of Solid State Photomultiplier signals with crosstalk
- Calibration and performance of the photon sensor response of FACT -- The First G-APD Cherenkov telescope
- Study of the breakdown voltage of SiPMs
- Influence of X-ray Irradiation on the Properties of the Hamamatsu Silicon Photomultiplier S10362-11-050C
- An Educational Kit Based on a Modular Silicon Photomultiplier System
Cited by in corpus (12)
- Radiation damage of SiPMs
- Characterisation of SiPMs
- Characterisation of a large area silicon photomultiplier
- Tests of a dual-readout fiber calorimeter with SiPM light sensors
- The Light-Trap: A novel concept for a large SiPM-based pixel for Very High Energy gamma-ray astronomy and beyond
- Characterisation of plastic scintillator paddles and lightweight MWPCs for the MID subsystem of ALICE 3
- Large scale characterization and calibration strategy of a SiPM-based camera for gamma-ray astronomy
- Analysis methods for highly radiation-damaged SiPMs
- Development of a multi-channel power supply for silicon photo-multipliers used with inorganic scintillators
- First-principle event reconstruction by time-charge readouts for the Taishan Antineutrino Observatory
- Development of a compact muon veto for the NUCLEUS experiment
- A computer program to simulate the response of SiPMs