A model based DC analysis of SiPM breakdown voltages
arXiv:1606.07805 · doi:10.1016/j.nima.2017.01.002
Abstract
A new method to determine the breakdown voltage of SiPMs is presented. It is backed up by a DC model which describes the breakdown phenomenon by distinct avalanche turn-on () and turn off () voltages. It is shown that is related to the 'breakdown voltage' that previous DC methods derive from simple reverse current-voltage measurements, while is the 'real' breakdown voltage commonly obtained from complex gain-voltage measurements. The proposed method reveals how the microcell population distributes around and . It is found that if this distribution is assumed to be normal, then both voltages and even their standard deviation can readily be extracted from current-voltage curves. Measurements are in good agreement with the theoretical model.
References in corpus (1)
Cited by in corpus (9)
- Characterisation of a large area silicon photomultiplier
- In-orbit Radiation Damage Characterization of SiPMs in the GRID-02 CubeSat Detector
- A Comparison of the Effects of Neutron and Gamma Radiation in Silicon Photomultipliers
- Modelling the Nonlinear Response of Silicon Photomultipliers
- Neutron irradiation test of Hamamatsu, SensL and AdvanSiD UV-extended SiPMs
- Performance of the electromagnetic and hadronic prototype segments of the ALICE Forward Calorimeter
- Properties of large SiPM at room temperature
- Temperature-Dependent Calibration Procedures for the Silicon Photomultiplier Readout of the Cosmic Ray Veto Detector for the Mu2e Experiment
- Characterization of silicon photomultipliers for their application in muon scattering tomography