Design and performance of dual-polarization lumped-element kinetic inductance detectors for millimeter-wave polarimetry
arXiv:1710.02239 · doi:10.1051/0004-6361/201732044
Abstract
Lumped-element kinetic inductance detectors (LEKIDs) are an attractive technology for millimeter-wave observations that require large arrays of extremely low-noise detectors. We designed, fabricated and characterized 64-element (128 LEKID) arrays of horn-coupled, dual-polarization LEKIDs optimized for ground-based CMB polarimetry. Our devices are sensitive to two orthogonal polarizations in a single spectral band centered on 150 GHz with . The mm square arrays are designed to be tiled into the focal plane of an optical system. We demonstrate the viability of these dual-polarization LEKIDs with laboratory measurements. The LEKID modules are tested with an FPGA-based readout system in a sub-kelvin cryostat that uses a two-stage adiabatic demagnetization refrigerator. The devices are characterized using a blackbody and a millimeter-wave source. The polarization properties are measured with a cryogenic stepped half-wave plate. We measure the resonator parameters and the detector sensitivity, noise spectrum, dynamic range, and polarization response. The resonators have internal quality factors approaching . The detectors have uniform response between orthogonal polarizations and a large dynamic range. The detectors are photon-noise limited above 1 pW of absorbed power. The noise-equivalent temperatures under a 3.4 K blackbody load are . The polarization fractions of detectors sensitive to orthogonal polarizations are >80%. The entire array is multiplexed on a single readout line, demonstrating a multiplexing factor of 128. The array and readout meet the requirements for 4 arrays to be read out simultaneously for a multiplexing factor of 512. This laboratory study demonstrates the first dual-polarization LEKID array optimized for CMB polarimetry and shows the readiness of the detectors for on-sky observations.
arXiv commentAccepted in Astronomy & Astrophysics, revised version. 11 pages, 8 figures
References in corpus (27)
- Statistics of Cosmic Microwave Background Polarization
- Signature of Gravity Waves in Polarization of the Microwave Background
- A limit on the detectability of the energy scale of inflation
- An analysis method for asymmetric resonator transmission applied to superconducting devices
- ARCONS: A 2024 Pixel Optical through Near-IR Cryogenic Imaging Spectrophotometer
- The NIKA2 large field-of-view millimeter continuum camera for the 30-m IRAM telescope
- The NIKA2 instrument, a dual-band kilopixel KID array for millimetric astronomy
- A kilo-pixel imaging system for future space based far-infrared observatories using microwave kinetic inductance detectors
- The Bolocam Galactic Plane Survey. XIV. Physical Properties of Massive Starless and Star Forming Clumps
- High optical efficiency and photon noise limited sensitivity of microwave kinetic inductance detectors using phase readout
- MAXIPOL: Cosmic Microwave Background Polarimetry Using a Rotating Half-Wave Plate
- Crosstalk Reduction for Superconducting Microwave Resonator Arrays
- First observation of the thermal Sunyaev-Zel'dovich effect with kinetic inductance detectors
- Two-level system noise reduction for Microwave Kinetic Inductance Detectors
- Photon-noise limited sensitivity in titanium nitride kinetic inductance detectors
- Horn-Coupled, Commercially-Fabricated Aluminum Lumped-Element Kinetic Inductance Detectors for Millimeter Wavelengths
- A CubeSat for Calibrating Ground-Based and Sub-Orbital Millimeter-Wave Polarimeters (CalSat)
- MAKO: a pathfinder instrument for on-sky demonstration of low-cost 350 micron imaging arrays
- Direct Detection of SDSS J0926+3624 Orbital Expansion with ARCONS
- Photon noise from chaotic and coherent millimeter-wave sources measured with horn-coupled, aluminum lumped-element kinetic inductance detectors
- Optical Demonstration of THz, Dual-Polarization Sensitive Microwave Kinetic Inductance Detectors
- Design and Testing of Kinetic Inductance Detectors Made of Titanium Nitride
- The non-equilibrium response of a superconductor to pair-breaking radiation measured over a broad frequency band
- Low Noise Titanium Nitride KIDs for SuperSpec: A Millimeter-Wave On-Chip Spectrometer
- High quality factor manganese-doped aluminum lumped-element kinetic inductance detectors sensitive to frequencies below 100 GHz
- Development of dual-polarization LEKIDs for CMB observations
- Polarization Sensitive Multi-Chroic MKIDs
Cited by in corpus (7)
- Kinetic Inductance Detectors for the OLIMPO experiment: in--flight operation and performance
- The short wavelength instrument for the polarization explorer balloon-borne experiment: Polarization modulation issues
- Development of Multi-Chroic MKIDs for Next-Generation CMB Polarization Studies
- Total power horn-coupled 150 GHz LEKID array for space applications
- A Scalable Cryogenic LED Module for Selectively Illuminating Kinetic Inductance Detector Arrays
- Response of a Cold-Electron Bolometer in a coplanar antenna system
- A kinetic inductance detectors array design for high background conditions at 150 GHz