Photon noise from chaotic and coherent millimeter-wave sources measured with horn-coupled, aluminum lumped-element kinetic inductance detectors
arXiv:1510.06609 · doi:10.1063/1.4942804
Abstract
We report photon-noise limited performance of horn-coupled, aluminum lumped-element kinetic inductance detectors at millimeter wavelengths. The detectors are illuminated by a millimeter-wave source that uses an active multiplier chain to produce radiation between 140 and 160 GHz. We feed the multiplier with either amplified broadband noise or a continuous-wave tone from a microwave signal generator. We demonstrate that the detector response over a 40 dB range of source power is well-described by a simple model that considers the number of quasiparticles. The detector noise-equivalent power (NEP) is dominated by photon noise when the absorbed power is greater than approximately 1 pW, which corresponds to , referenced to absorbed power. At higher source power levels we observe the relationships between noise and power expected from the photon statistics of the source signal: for broadband (chaotic) illumination and for continuous-wave (coherent) illumination.
arXiv commentMatches published version (which is open access) and includes supplemental material
References in corpus (10)
- A semi-empirical model for two-level system noise in superconducting microresonators
- Fluctuations in the electron system of a superconductor exposed to a photon flux
- Photon noise limited radiation detection with lens-antenna coupled Microwave Kinetic Inductance Detectors
- High optical efficiency and photon noise limited sensitivity of microwave kinetic inductance detectors using phase readout
- Quasiparticle generation efficiency in superconducting thin-films
- Photon-noise limited sensitivity in titanium nitride kinetic inductance detectors
- Horn-Coupled, Commercially-Fabricated Aluminum Lumped-Element Kinetic Inductance Detectors for Millimeter Wavelengths
- Photon noise from chaotic and coherent millimeter-wave sources measured with horn-coupled, aluminum lumped-element kinetic inductance detectors
- The non-equilibrium response of a superconductor to pair-breaking radiation measured over a broad frequency band
- On the use of shot noise for photon counting
Cited by in corpus (14)
- A kilo-pixel imaging system for future space based far-infrared observatories using microwave kinetic inductance detectors
- Interplay between kinetic inductance, non-linearity and quasiparticle dynamics in granular aluminum MKIDs
- Ultra-sensitive Super-THz Microwave Kinetic Inductance Detectors for future space telescopes
- Wideband on-chip terahertz spectrometer based on a superconducting filterbank
- Design and performance of dual-polarization lumped-element kinetic inductance detectors for millimeter-wave polarimetry
- Photon noise from chaotic and coherent millimeter-wave sources measured with horn-coupled, aluminum lumped-element kinetic inductance detectors
- LEKID sensitivity for space applications between 80 and 600 GHz
- Optimizing single microwave-photon detection: Input-Output theory
- Development of Multi-Chroic MKIDs for Next-Generation CMB Polarization Studies
- Development of dual-polarization LEKIDs for CMB observations
- Polarization Sensitive Multi-Chroic MKIDs
- A forecast of the sensitivity on the measurement of the optical depth to reionization with the GroundBIRD experiment
- A multi-chroic kinetic inductance detectors array using hierarchical phased array antenna
- AMKID -- a large KID-based camera at the APEX telescope