Dose rate effects in the radiation damage of the plastic scintillators of the CMS Hadron Endcap Calorimeter
arXiv:1608.07267 · doi:10.1088/1748-0221/11/10/T10004
Abstract
We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given dose is larger for lower dose rate exposures. The results agree with previous measurements of dose rate effects, but are stronger due to the very low dose rates probed. We show that the scaling with dose rate is consistent with that expected from diffusion effects.
Cited by in corpus (6)
- Individual Pulse Monitoring and Dose Control System for Pre-Clinical Implementation of FLASH-RT
- Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter
- Dose rate effects in radiation-induced changes to phenyl-based polymeric scintillators
- Effects of oxygen on the optical properties of phenyl-based scintillators during irradiation and recovery
- A study of radiation tolerance in optical cements
- Study of the Radiation Hardness of the ATLAS Tile Calorimeter Optical Instrumentation with Run 2 data