TREX-DM: a low-background Micromegas-based TPC for low-mass WIMP detection
arXiv:1512.01455 · doi:10.1140/epjc/s10052-016-4372-6
Abstract
If Dark Matter is made of Weakly Interacting Massive Particles (WIMPs) with masses below 20 GeV, the corresponding nuclear recoils in mainstream WIMP experiments are of energies too close, or below, the experimental threshold. Gas Time Projection Chambers (TPCs) can be operated with a variety of target elements, offer good tracking capabilities and, on account of the amplification in gas, very low thresholds are achievable. Recent advances in electronics and in novel radiopure TPC readouts, especially micro-mesh gas structure (Micromegas), are improving the scalability and low-background prospects of gaseous TPCs. Here we present TREX-DM, a prototype to test the concept of a Micromegas-based TPC to search for low-mass WIMPs. The detector is designed to host an active mass of 0.300 kg of Ar at 10 bar, or alternatively 0.160 kg of Ne at 10 bar, with an energy threshold below 0.4 keVee, and is fully built with radiopure materials. We will describe the detector in detail, the results from the commissioning phase on surface, as well as a preliminary background model. The anticipated sensitivity of this technique may go beyond current experimental limits for WIMPs of masses of 2-8 GeV.
arXiv commentManuscript submitted to Eur. Phys. J. C. Major revision following the comments by the referee
References in corpus (48)
- Particle Dark Matter: Evidence, Candidates and Constraints
- Supersymmetric Dark Matter
- First results from the LUX dark matter experiment at the Sanford Underground Research Facility
- Dark Matter Results from 225 Live Days of XENON100 Data
- Results from the Final Exposure of the CDMS II Experiment
- Results from 730 kg days of the CRESST-II Dark Matter Search
- Implication of neutrino backgrounds on the reach of next generation dark matter direct detection experiments
- Final model independent result of DAMA/LIBRA-phase1
- Asymmetric Dark Matter: Theories, Signatures, and Constraints
- Search for Low-Mass WIMPs with SuperCDMS
- Micromegas in a Bulk
- Compatibility of DAMA/LIBRA dark matter detection with other searches
- CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact Germanium Detectors
- WIMP-Search Results from the Second CDMSlite Run
- Results on light dark matter particles with a low-threshold CRESST-II detector
- Search for squarks and gluinos with the ATLAS detector in final states with jets and missing transverse momentum using TeV proton--proton collision data
- Isospin-Violating Dark Matter
- Phase-space structure in the local dark matter distribution and its signature in direct detection experiments
- The event generator DECAY4 for simulation of double beta processes and decay of radioactive nuclei
- The case for a directional dark matter detector and the status of current experimental efforts
- Results from the first use of low radioactivity argon in a dark matter search
- Results on low mass WIMPs using an upgraded CRESST-II detector
- Systematic study of trace radioactive impurities in candidate construction materials for EXO-200
- Search for supersymmetry in hadronic final states using MT2 in pp collisions at sqrt(s) = 7 TeV
- WIMP-nucleon scattering with heavy WIMP effective theory
- Halo-to-Halo Similarity and Scatter in the Velocity Distribution of Dark Matter
- Limits on light WIMPs from the CDEX-1 experiment with a p-type point-contact germanium detector at the China Jingping Underground Laboratory
- First Dark Matter Search Results from a Surface Run of the 10-L DMTPC Directional Dark Matter Detector
- Improved WIMP-search reach of the CDMS II germanium data
- Dependence of direct detection signals on the WIMP velocity distribution
- Radiopurity of Micromegas readout planes
- A Study of the Residual 39Ar Content in Argon from Underground Sources
- A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research
- Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atmospheres
- High pressure operation of the triple-GEM detector in pure Ne, Ar and Xe
- Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment
- Micromegas detector developments for Dark Matter directional detection with MIMAC
- Neutron background at the Canfranc Underground Laboratory and its contribution to the IGEX-DM dark matter experiment
- Gaseous time projection chambers for rare event detection: Results from the T-REX project. I. Double beta decay
- Characterization of microbulk detectors in argon- and neon-based mixtures
- Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy -rays
- Micromegas readouts for double beta decay searches
- Gaseous time projection chambers for rare event detection: Results from the T-REX project. II. Dark matter
- Pattern recognition of Xe double beta decay events and background discrimination in a high pressure Xenon TPC
- Low energy electron/recoil discrimination for directional Dark Matter detection
- Description and commissioning of NEXT-MM prototype: first results from operation in a Xenon-Trimethylamine gas mixture
- Scintillation efficiency of liquid argon in low energy neutron-argon scattering
- Status of R&D on Micromegas for Rare Event Searches: The T-REX project
Cited by in corpus (23)
- New experimental approaches in the search for axion-like particles
- Readout technologies for directional WIMP Dark Matter detection
- Gaseous and dual-phase time projection chambers for imaging rare processes
- Cosmogenic production of tritium in dark matter detectors
- Cosmogenic activation of materials
- Background assessment for the TREX Dark Matter experiment
- Review on dark matter searches
- Enhanced low-energy supernova burst detection in large liquid argon time projection chambers enabled by Q-Pix
- Design and commissioning of a 600 L Time Projection Chamber with Microbulk Micromegas
- The TPC detector of PandaX-III Neutrinoless Double Beta Decay experiment
- The TREX-DM experiment at the Canfranc Underground Laboratory
- Detectors and Concepts for sub-100 ps timing with gaseous detectors
- Double Beta Decay Experiments at Canfranc Underground Laboratory
- The role of small scale experiments in the direct detection of dark matter
- Microbulk Micromegas in non-flammable mixtures of argon and neon at high pressure
- AlphaCAMM, a Micromegas-based camera for high-sensitivity screening of alpha surface contamination
- Calibration of a Micromegas-based Gaseous Time Projection Chamber Using Cosmic Ray Muons
- Searching for light WIMPS in view of neutron decay to dark matter
- Micromegas with GEM preamplification for enhanced energy threshold in low-background gaseous time projection chambers
- Small scale direct dark matter search experiments
- Low-energy threshold demonstration for dark matter searches in TREX-DM with an Ar source produced at CNA HiSPANoS
- State of the Art in Direct Dark Matter Detectors: Technologies, Performance, and Future Directions
- The potential of discrimination methods in a high pressure xenon TPC for the search of the neutrinoless double-beta decay of Xe-136