Radiopurity of Micromegas readout planes
arXiv:1005.2022 · doi:10.1016/j.astropartphys.2010.09.003
Abstract
Micromesh Gas Amplification Structures (Micromegas) are being used in an increasing number of Particle Physics applications since their conception fourteen years ago. More recently, they are being used or considered as readout of Time Projection Chambers (TPCs) in the field of Rare Event searches (dealing with dark matter, axions or double beta decay). In these experiments, the radiopurity of the detector components and surrounding materials is measured and finely controlled in order to keep the experimental background as low as possible. In the present paper, the first measurement of the radiopurity of Micromegas planes obtained by high purity germanium spectrometry in the low background facilities of the Canfranc Underground Laboratory (LSC) is presented. The obtained results prove that Micromegas readouts of the microbulk type are currently manufactured with radiopurity levels below 30 microBq/cm2 for Th and U chains and ~60 microBq/cm2 for 40K, already comparable to the cleanest detector components of the most stringent low background experiments at present. Taking into account that the studied readouts were manufactured without any specific control of the radiopurity, it should be possible to improve these levels after dedicated development.
15 pages, 2 figures
References in corpus (12)
- Micromegas in a Bulk
- First results from the CERN Axion Solar Telescope (CAST)
- An improved limit on the axion-photon coupling from the CAST experiment
- Probing eV-scale axions with CAST
- The case for a directional dark matter detector and the status of current experimental efforts
- First underground results with NEWAGE-0.3a direction-sensitive dark matter detector
- The Micromegas detector of the CAST experiment
- Energy resolution of alpha particles in a microbulk Micromegas detector at high pressure Argon and Xenon mixtures
- NEXT, a HPGXe TPC for neutrinoless double beta decay searches
- First measurement of the Head-Tail directional nuclear recoil signature at energies relevant to WIMP dark matter searches
- Charge amplification concepts for direction-sensitive dark matter detectors
- Physics at Underground Laboratories: Direct Detection of Dark Matter
Cited by in corpus (34)
- Conceptual Design of the International Axion Observatory (IAXO)
- Towards a new generation axion helioscope
- CAST search for sub-eV mass solar axions with 3He buffer gas
- Readout technologies for directional WIMP Dark Matter detection
- New solar axion search in CAST with He filling
- Gaseous and dual-phase time projection chambers for imaging rare processes
- Radiopurity control in the NEXT-100 double beta decay experiment: procedures and initial measurements
- Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atmospheres
- Micromegas-TPC operation at high pressure in xenon-trimethylamine mixtures
- Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment
- TREX-DM: a low-background Micromegas-based TPC for low-mass WIMP detection
- Gaseous time projection chambers for rare event detection: Results from the T-REX project. I. Double beta decay
- Background assessment for the TREX Dark Matter experiment
- Characterization of microbulk detectors in argon- and neon-based mixtures
- Radiopurity assessment of the energy readout for the NEXT double beta decay experiment
- Gaseous time projection chambers for rare event detection: Results from the T-REX project. II. Dark matter
- Description and commissioning of NEXT-MM prototype: first results from operation in a Xenon-Trimethylamine gas mixture
- First results of a large-area cryogenic gaseous photomultiplier coupled to a dual-phase liquid xenon TPC
- Exploring 0.1-10eV axions with a new helioscope concept
- Modelling the behaviour of microbulk Micromegas in Xenon/trimethylamine gas
- Status of R&D on Micromegas for Rare Event Searches: The T-REX project
- Microbulk Micromegas for the search of 0 of 136Xe in the PandaX-III experiment
- CAST microbulk micromegas in the Canfranc Underground Laboratory
- Micromegas-TPC operation at high pressure in Xenon-trimethylamine mixtures
- TREX-DM: a low background Micromegas-based TPC for low mass WIMP detection
- Microbulk Micromegas in non-flammable mixtures of argon and neon at high pressure
- Detection of Alpha Particles and Low Energy Gamma Rays by Thermo-Bonded Micromegas in Xenon Gas
- Low X-ray bakground measurements at the Underground Canfranc Laboratory
- Low Background Micromegas in CAST
- Micromegas with GEM preamplification for enhanced energy threshold in low-background gaseous time projection chambers
- TREX-DM: a low background Micromegas-based TPC for low-mass WIMP detection
- Solar Axion search with Micromegas detectors in the CAST Experiment with He as buffer gas
- Lowering the background level and the energy threshold of Micromegas x-ray detectors for axion searches
- Low-energy threshold demonstration for dark matter searches in TREX-DM with an Ar source produced at CNA HiSPANoS