The scintillation of liquid argon
arXiv:1511.07718 · doi:10.1209/0295-5075/91/62002
Abstract
A spectroscopic study of liquid argon from the vacuum ultraviolet at 110 nm to 1000 nm is presented. Excitation was performed using continuous and pulsed 12 keV electron beams. The emission is dominated by the analogue of the so called 2nd excimer continuum. Various additional emission features were found. The time structure of the light emission has been measured for a set of well defined wavelength positions. The results help to interpret literature data in the context of liquid rare gas detectors in which the wavelength information is lost due to the use of wavelength shifters.
4 pages, 5 figures
References in corpus (1)
Cited by in corpus (55)
- Dark Matter and Dark Energy Interactions: Theoretical Challenges, Cosmological Implications and Observational Signatures
- Liquid noble gas detectors for low energy particle physics
- Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB
- First results from the DEAP-3600 dark matter search with argon at SNOLAB
- Evidence of delayed light emission of TetraPhenyl Butadiene excited by liquid Argon scintillation light
- Revealing neutral bremsstrahlung in two-phase argon electroluminescence
- Calorimetry for low-energy electrons using charge and light in liquid argon
- Review of Liquid Argon Detector Technologies in the Neutrino Sector
- Polyethylene naphthalate film as a wavelength shifter in liquid argon detectors
- A measurement of the group velocity of scintillation light in liquid argon
- Electroluminescence and electron avalanching in two-phase detectors
- Cryogenic R5912-20Mod Photomultiplier Tube Characterization for the ProtoDUNE Dual Phase Detector
- Intense Vacuum-Ultraviolet and Infrared Scintillation of Liquid Ar-Xe Mixtures
- Use of polyethylene naphthalate as a self-vetoing structural material
- Attenuation of vacuum ultraviolet light in liquid argon
- Table-top setup for investigating the scintillation properties of liquid argon
- Ion-beam excitation of liquid argon
- On the Electric Breakdown in Liquid Argon at Centimeter Scale
- Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
- Attenuation of vacuum ultraviolet light in pure and xenon-doped liquid argon - an approach to an assignment of the near-infrared emission from the mixture
- Light emission from particle beam induced plasma - An overview
- Scintillation Light in SBND: Simulation, Reconstruction, and Expected Performance of the Photon Detection System
- Spectroscopic analysis of the argon scintillation with a wavelength sensitive particle detector
- Attenuation measurements of vacuum ultraviolet light in liquid argon revisited
- Neutral bremsstrahlung in two-phase argon electroluminescence: further studies and possible applications
- The DarkSide-20k experiment
- Measurement of the Photon Detection Efficiency of Hamamatsu VUV4 SiPMs at Cryogenic Temperature
- Scintillation and optical properties of xenon-doped liquid argon
- Intense Infrared Scintillation of Liquid Ar-Xe Mixtures
- Production and validation of scintillating structural components from low-background Poly(ethylene naphthalate)
- Near-infrared scintillation of liquid argon
- Liquid argon light collection and veto modeling in GERDA Phase II
- Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC
- Optical properties of low background PEN structural components for the LEGEND-200 experiment
- Some considerations about cosmogenic production of radioactive isotopes in Ar as target for the next neutrino experiments
- Doping Liquid Argon with Xenon in ProtoDUNE Single-Phase: Effects on Scintillation Light
- Photon detector system timing performance in the DUNE 35-ton prototype liquid argon time projection chamber
- ProtoDUNE-DP Light Acquisition and Calibration Software
- Liquid argon scintillation response to electronic recoils between -- in a high light yield single-phase detector
- Study of visible-light emission in pure and methane-doped liquid argon
- About detecting very low mass black holes in LAr detectors
- Direct Measurement of the Ar Half-life from 3.4 Years of Data with the DEAP-3600 Detector
- Development of a high-light-yield liquid argon detector using tetraphenyl butadiene and silicon photomultiplier array
- Near-infrared scintillation of liquid argon: recent results obtained with the NIR facility at Fermilab
- In-situ measurement of the scintillation light attenuation in liquid argon in the GERDA experiment
- Differences in the response of two light guide technologies and two readout technologies after an exchange of liquid argon in the dewar
- Measurement of the attenuation length of argon scintillation light in the ArDM LAr TPC
- Developing Scintillation Light Readout Simulation for the SBND experiment
- SBC-SNOLAB scintillation system and SiPM implementation for dark matter searches
- First use of large area SiPM matrices coupled with NaI(Tl) scintillating crystal for low energy dark matter search
- Demonstrating a broadband Photon Detection Efficiency model on VUV sensitive Silicon Photomultipliers
- A nonlinear multiphysics model for the design validation of the ASTAROTH copper-steel cryogenic chamber
- Usage of PEN as self-vetoing structural material in low background experiments
- ASTAROTH: A Novel Detector for Dark Matter Direct Detection Using Cryogenic SiPMs
- A Novel Manufacturing Process for Glass THGEMs and First Characterisation in an Optical Gaseous Argon TPC