Scintillation Light from Cosmic-Ray Muons in Liquid Argon
arXiv:1408.1763 · doi:10.1088/1748-0221/11/05/P05016
Abstract
This paper reports the results of an experiment to directly measure the time-resolved scintillation signal from the passage of cosmic-ray muons through liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches. The experiment was carried out at the TallBo dewar facility at Fermilab using prototype light guide detectors and electronics developed for the Deep Underground Neutrino Experiment. Two models are presented for the time structure of the scintillation light, a phenomenological model and a composite model. Both models find s for the decay time constant of the Ar triplet state. These models also show that the identification of the "early" light fraction in the phenomenological model, of the signal, with the total light from singlet decays is an underestimate. The total fraction of singlet light is , where the increase over is from singlet light emitted by the wavelength shifter through processes with long decay constants. The models were further used to compute the experimental particle identification parameter , the fraction of light coming in a short time window after the trigger compared with the light in the total recorded waveform. The models reproduce quite well the typical experimental value found by dark matter and double -decay experiments, which suggests this parameter provides a robust metric for discriminating electrons and muons from more heavily ionizing particles.
arXiv comment30 pages, 10 figures. This experiment has been repeated with improved data quality and analysis techniques
References in corpus (8)
- First Results from the DarkSide-50 Dark Matter Experiment at Laboratori Nazionali del Gran Sasso
- Characterisation Studies of Silicon Photomultipliers
- The scintillation of liquid argon
- Fluorescence Efficiency and Visible Re-emission Spectrum of Tetraphenyl Butadiene Films at Extreme Ultraviolet Wavelengths
- Evidence of delayed light emission of TetraPhenyl Butadiene excited by liquid Argon scintillation light
- A Measurement of the Absorption of Liquid Argon Scintillation Light by Dissolved Nitrogen at the Part-Per-Million Level
- Demonstration of a Lightguide Detector for Liquid Argon TPCs
- Argon Purification Studies and a Novel Liquid Argon Re-circulation System
Cited by in corpus (10)
- The X-ARAPUCA: An improvement of the ARAPUCA device
- A 4 tonne demonstrator for large-scale dual-phase liquid argon time projection chambers
- Tetraphenyl Butadiene Emanation and Bulk Fluorescence from Wavelength Shifting Coatings in Liquid Argon
- A Novel Use of Light Guides and Wavelength Shifting Plates for the Detection of Scintillation Photons in Large Liquid Argon Detectors
- Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC
- Photon detector system timing performance in the DUNE 35-ton prototype liquid argon time projection chamber
- A measurement of absolute efficiency of the ARAPUCA photon detector in Liquid Argon
- Differences in the response of two light guide technologies and two readout technologies after an exchange of liquid argon in the dewar
- Photon Detection System Designs for the Deep Underground Neutrino Experiment
- Scintillation light detection in the 6-m drift length ProtoDUNE Dual Phase liquid argon TPC