Differences in the response of two light guide technologies and two readout technologies after an exchange of liquid argon in the dewar
arXiv:1912.05987 · doi:10.1016/j.nima.2020.164240
Abstract
In this investigation the response to the scintillation light generated by through-going cosmic muons in liquid argon (LAr) was measured by two light guide technologies and two readout technologies after five weeks of running in the TallBo dewar at Fermilab. The response was remeasured after the dewar was drained of LAr, refilled, and then run again for an additional four weeks. After the dewar was refilled, there was clear evidence that the scintillation signal had dropped significantly. The two light guide technologies were developed at Indiana University and MIT/Fermilab. The two readout technologies were boards that passively or actively ganged 12 Hamamatsu MPPCs. Two possible explanations were identified for the degraded signal: the response of the two light guide technologies degraded due to damage caused by thermal cycling, and/or unknown differences in the trace residual Xe contamination in the fills of LAr led to the observed drop in scintillation light. Neither absorption nor quenching by N2, O2, and H2O contamination can account for the degradation. Neither the individual Hamamatsu MPPCs nor the passive/active ganging boards appear to have been affected by the thermal cycling. The path length distributions of the cosmics traversing the dewar appear quite similar in both event samples.
arXiv commentpaper 27 pages, 5 figures; appendix 14 pages, 16 figures; submitted article replaced by published article
References in corpus (13)
- The scintillation of liquid argon
- Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 1: The LBNF and DUNE Projects
- Oxygen contamination in liquid Argon: combined effects on ionization electron charge and scintillation light
- Effects of Nitrogen contamination in liquid Argon
- A Measurement of the Absorption of Liquid Argon Scintillation Light by Dissolved Nitrogen at the Part-Per-Million Level
- Demonstration of a Lightguide Detector for Liquid Argon TPCs
- Pulse-shape discrimination and energy resolution of a liquid-argon scintillator with xenon doping
- Tetraphenyl Butadiene Emanation and Bulk Fluorescence from Wavelength Shifting Coatings in Liquid Argon
- A Novel Use of Light Guides and Wavelength Shifting Plates for the Detection of Scintillation Photons in Large Liquid Argon Detectors
- Argon Purification Studies and a Novel Liquid Argon Re-circulation System
- Attenuation of vacuum ultraviolet light in pure and xenon-doped liquid argon - an approach to an assignment of the near-infrared emission from the mixture
- Scintillation Light from Cosmic-Ray Muons in Liquid Argon
- Improved TPB-coated Light Guides for Liquid Argon TPC Light Detection Systems