Cryogenic preamplification of a single-electron-transistor using a silicon-germanium heterojunction-bipolar-transistor
arXiv:1509.08201 · doi:10.1063/1.4921308
Abstract
We examine a silicon-germanium heterojunction bipolar transistor (HBT) for cryogenic pre-amplification of a single electron transistor (SET). The SET current modulates the base current of the HBT directly. The HBT-SET circuit is immersed in liquid helium, and its frequency response from low frequency to several MHz is measured. The current gain and the noise spectrum with the HBT result in a signal-to-noise-ratio (SNR) that is a factor of 10-100 larger than without the HBT at lower frequencies. The transition frequency defined by SNR = 1 has been extended by as much as a factor of 10 compared to without the HBT amplification. The power dissipated by the HBT cryogenic pre-amplifier is approximately 5 nW to 5 μW for the investigated range of operation. The circuit is also operated in a single electron charge read-out configuration in the time-domain as a proof-of-principle demonstration of the amplification approach for single spin read-out.
arXiv commentReprinted with permission from M. J. Curry, et alii. Copyright 2015, AIP Publishing LLC. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the AIP Publishing LLC. 5 pages, 4 figures
References in corpus (15)
- Circuit Quantum Electrodynamics: Coherent Coupling of a Single Photon to a Cooper Pair Box
- Single-shot read-out of an individual electron spin in a quantum dot
- Silicon Quantum Electronics
- A single-atom electron spin qubit in silicon
- Single-shot readout of an electron spin in silicon
- Circuit Quantum Electrodynamics with a Spin Qubit
- Single-shot readout of electron spin states in a quantum dot using spin-dependent tunnel rates
- Rapid Single-Shot Measurement of a Singlet-Triplet Qubit
- Dispersive Readout of a Few-Electron Double Quantum Dot with Fast rf Gate-Sensors
- Fast sensing of double-dot charge arrangement and spin state with an rf sensor quantum dot
- A high-sensitivity gate-based charge sensor in silicon
- Electron spin decoherence in isotope-enriched silicon
- Josephson directional amplifier for quantum measurement of superconducting circuits
- A cryogenic amplifier for fast real-time detection of single-electron tunneling
- Radio-frequency dispersive detection of donor atoms in a field-effect transistor
Cited by in corpus (11)
- Quantum CNOT Gate for Spins in Silicon
- Scalable gate architecture for densely packed semiconductor spin qubits
- Semiconductor Quantum Computation
- Silicon quantum processor with robust long-distance qubit couplings
- Probing single electrons across 300 mm spin qubit wafers
- Spin-orbit Interactions for Singlet-Triplet Qubits in Silicon
- Direct Detection of MeV-Scale Dark Matter Utilizing Germanium Internal Amplification for the Charge Created by the Ionization of Impurities
- All-electrical universal control of a double quantum dot qubit in silicon MOS
- Cryogenic amplification of image-charge detection for readout of quantum states of electrons on liquid helium
- Operating two exchange-only qubits in parallel
- Fast measurement of carbon nanotube resonator amplitude with a heterojunction bipolar transistor