Microcalorimeter Spectroscopy at High Pulse Rates: a Multi-Pulse Fitting Technique
arXiv:1503.05989 · doi:10.1088/0067-0049/219/2/35
Abstract
Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each sensor must be able to measure hundreds or even thousands of photon energies per second. Current "optimal filtering" approaches to achieve the best possible energy resolution work only for photons well isolated in time, a requirement in direct conflict with the need for high-rate measurements. We describe a new analysis procedure to allow fitting for the pulse height of all photons even in the presence of heavy pulse pile-up. In the limit of isolated pulses, the technique reduces to the standard optimal filtering with long records. We employ reasonable approximations to the noise covariance function in order to render multi-pulse fitting computationally viable even for very long data records. The technique is employed to analyze x-ray emission spectra at 600 eV and 6 keV at rates up to 250 counts per second in microcalorimeters having exponential signal decay times of approximately 1.2 ms.
This version exactly matches the submission to journal
References in corpus (2)
Cited by in corpus (17)
- The Practice of Pulse Processing
- Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range
- A Reassessment of Absolute Energies of the X-ray L Lines of Lanthanide Metals
- A Transition-edge Sensor-based X-ray Spectrometer for the Study of Highly Charged Ions at the National Institute of Standards and Technology Electron Beam Ion Trap
- Algorithms for Identification of Nearly-Coincident Events in Calorimetric Sensors
- Absolute energies and emission line shapes of the L x-ray transitions of lanthanide metals
- Approaches to the Optimal Nonlinear Analysis of Microcalorimeter Pulses
- When "Optimal Filtering" Isn't
- Improving the dynamic range of single photon counting kinetic inductance detectors
- Transition-Edge Sensors for cryogenic X-ray imaging spectrometers
- A novel approach for nearly-coincident events rejection
- A robust principal component analysis for outlier identification in messy microcalorimeter data
- Multi-pulse fitting of Transition Edge Sensor signals from a near-infrared continuous-wave source
- Optimal Filtering of Overlapped Pulses in Microcalorimeter Data
- The matrix optimum filter for Low Temperature Detectors dead-time reduction
- Improving the energy resolution of photon counting Microwave Kinetic Inductance Detectors using principal component analysis
- Data reduction for a calorimetrically measured spectrum of the ECHo-1k experiment