The Practice of Pulse Processing
arXiv:1511.03950 · doi:10.1007/s10909-015-1380-0
Abstract
The analysis of data from x-ray microcalorimeters requires great care; their excellent intrinsic energy resolution cannot usually be achieved in practice without a statistically near-optimal pulse analysis and corrections for important systematic errors. We describe the essential parts of a pulse-analysis pipeline for data from x-ray microcalorimeters, including steps taken to reduce systematic gain variation and the unwelcome dependence of filtered pulse heights on the exact pulse-arrival time. We find these steps collectively to be essential tools for getting the best results from a microcalorimeter-based x-ray spectrometer.
Accepted for publication in J. Low Temperature Physics, special issue for the proceedings of the Low Temperature Detectors 16 conference
References in corpus (2)
Cited by in corpus (28)
- The Practice of Pulse Processing
- Eliminating the non-Gaussian spectral response of X-ray absorbers for transition-edge sensors
- A Reassessment of Absolute Energies of the X-ray L Lines of Lanthanide Metals
- SLAC Microresonator RF (SMuRF) Electronics: A tone-tracking readout system for superconducting microwave resonator arrays
- A Transition-edge Sensor-based X-ray Spectrometer for the Study of Highly Charged Ions at the National Institute of Standards and Technology Electron Beam Ion Trap
- L-Edge Spectroscopy of Dilute, Radiation-Sensitive Systems Using a Transition-Edge-Sensor Array
- Algorithms for Identification of Nearly-Coincident Events in Calorimetric Sensors
- Broad-band High-Energy Resolution Hard X-ray Spectroscopy using Transition Edge Sensors at SPring-8
- Design of a 3000-pixel transition-edge sensor x-ray spectrometer for microcircuit tomography
- Absolute energies and emission line shapes of the L x-ray transitions of lanthanide metals
- Kinetic inductance current sensor for visible to near-infrared wavelength transition-edge sensor readout
- Beamline Spectroscopy of Integrated Circuits With Hard X-ray Transition Edge Sensors at the Advanced Photon Source
- Approaches to the Optimal Nonlinear Analysis of Microcalorimeter Pulses
- A tabletop x-ray tomography instrument for nanometer-scale imaging: demonstration of the 1,000-element transition-edge sensor subarray
- When "Optimal Filtering" Isn't
- Improving the dynamic range of single photon counting kinetic inductance detectors
- Transition-Edge Sensors for cryogenic X-ray imaging spectrometers
- Resonant soft x-ray scattering from stripe-ordered LaBaCuO detected by a transition edge sensor array detector
- Energy calibration of nonlinear microcalorimeters with uncertainty estimates from Gaussian process regression
- Hard X-ray Fluorescence measurements with TESs at the Advanced Photon Source
- Mitigating the effects of charged particle strikes on TES arrays for exotic atom X-ray experiments
- A Highly Linear Calibration Metric for TES X-ray Microcalorimeters
- Controlled Shifts of X-ray Emission Lines Measured with Transition Edge Sensors at the Advanced Photon Source
- Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV
- The first cut is the cheapest: optimizing Athena/X-IFU-like TES detectors resolution by filter truncation
- Improving the energy resolution of photon counting Microwave Kinetic Inductance Detectors using principal component analysis
- Membrane-less phonon trapping and resolution enhancement in optical microwave kinetic inductance detectors
- Detecting and Correcting Gain Jumps in TES Microcalorimeters