Tenfold reduction of Brownian noise in optical interferometry
arXiv:1302.6489
Abstract
Thermally induced fluctuations impose a fundamental limit on precision measurement. In optical interferometry, the current bounds of stability and sensitivity are dictated by the excess mechanical damping of the high-reflectivity coatings that comprise the cavity end mirrors. Over the preceding decade, the mechanical loss of these amorphous multilayer reflectors has at best been reduced by a factor of two. Here we demonstrate a new paradigm in optical coating technology based on direct-bonded monocrystalline multilayers, which exhibit both intrinsically low mechanical loss and high optical quality. Employing these "crystalline coatings" as end mirrors in a Fabry-Pérot cavity, we obtain a finesse of 150,000. More importantly, at room temperature, we observe a thermally-limited noise floor consistent with a tenfold reduction in mechanical damping when compared with the best dielectric multilayers. These results pave the way for the next generation of ultra-sensitive interferometers, as well as for new levels of laser stability.
References in corpus (18)
- A sub-40 mHz linewidth laser based on a silicon single-crystal optical cavity
- Sr lattice clock at 1x10^{-16} fractional uncertainty by remote optical evaluation with a Ca clock
- Making optical atomic clocks more stable with level laser stabilization
- Compact, thermal-noise-limited optical cavity for diode laser stabilization at 1 x 10-15
- Thermal noise in interferometric gravitational wave detectors due to dielectric optical coatings
- Ultrastable lasers based on vibration insensitive cavities
- Comparison of Two Independent Sr Optical Clocks with 1e-17 Stability at 10^3 s
- Mechanical Loss in Tantala/Silica Dielectric Mirror Coatings
- Thermo-refractive noise in gravitational wave antennae
- Thermo-optic noise in coated mirrors for high-precision optical measurements
- Thermal noise in optical cavities revisited
- Thermoelastic effects at low temperatures and quantum limits in displacement measurements
- Full phase stabilization of a Yb:fiber femtosecond frequency comb via high-bandwidth transducers
- Radiation-pressure self-cooling of a micromirror in a cryogenic environment
- Optical Interferometers with Reduced Sensitivity to Thermal Noise
- Experimental limits for low-frequency space-time fluctuations from ultrastable optical resonators
- Optimal Light Beams and Mirror Shapes for Future LIGO Interferometers
- Waveguide grating mirror in a fully suspended 10 meter Fabry-Perot cavity