First demonstration of a sub-keV electron recoil energy threshold in a liquid argon ionization chamber
arXiv:1301.4290 · doi:10.1016/j.nima.2013.06.061
Abstract
We describe the first demonstration of a sub-keV electron recoil energy threshold in a dual-phase liquid argon time projection chamber. This is an important step in an effort to develop a detector capable of identifying the ionization signal resulting from nuclear recoils with energies of order a few keV and below. We obtained this result by observing the peaks in the energy spectrum at 2.82 keV and 0.27 keV, following the K- and L-shell electron capture decay of Ar-37, respectively. The Ar-37 source preparation is described in detail, since it enables calibration that may also prove useful in dark matter direct detection experiments. An internally placed Fe-55 x-ray source simultaneously provided another calibration point at 5.9 keV. We discuss the ionization yield and electron recombination in liquid argon at those three calibration energies.
References in corpus (3)
Cited by in corpus (18)
- Low-Mass Dark Matter Search with the DarkSide-50 Experiment
- First results from the NEWS-G direct dark matter search experiment at the LSM
- Investigation of background electron emission in the LUX detector
- A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST
- First measurement of the ionization yield of nuclear recoils in liquid argon
- Electron extraction efficiency study for dual-phase xenon dark matter experiments
- Simulation of argon response and light detection in the DarkSide-50 dual phase TPC
- Calibration of a two-phase xenon time projection chamber with a Ar source
- Constraining active-sterile neutrino transition magnetic moments at DUNE near and far detectors
- Experimental study of ionization yield of liquid xenon for electron recoils in the energy range 2.8 - 80 keV
- X-ray ionization yields and energy spectra in liquid argon
- Proportional electroluminescence in two-phase argon and its relevance to rare-event experiments
- Measurement of the ionization yield of nuclear recoils in liquid argon using a two-phase detector with electroluminescence gap
- Low-Energy (<10 keV) Electron Ionization and Recombination Model for a Liquid Argon Detector
- Further studies of proportional electroluminescence in two-phase argon
- Using Na and Kr to calibrate and study the properties of scintillation in xenon-doped liquid argon
- Antineutrino Detectors Remain Impractical for Nuclear Explosion Monitoring
- Low-energy threshold demonstration for dark matter searches in TREX-DM with an Ar source produced at CNA HiSPANoS