The K1.8BR spectrometer system at J-PARC
arXiv:1206.0077 · doi:10.1093/ptep/pts039
Abstract
A new spectrometer system was designed and constructed at the secondary beam line K1.8BR in the hadron hall of J-PARC to investigate interactions and -nuclear bound systems. The spectrometer consists of a high precision beam line spectrometer, a liquid He/He/D target system, a Cylindrical Detector System that surrounds the target to detect the decay particles from the target region, and a neutron time-of-flight counter array located 15 m downstream from the target position. Details of the design, construction, and performance of the detector components are described.
33 pages, 25 figures
References in corpus (12)
- Effective Kbar N interaction based on chiral SU(3) dynamics
- Variational calculation of the ppK^- system based on chiral SU(3) dynamics
- Indication of a deeply bound compact K-pp state formed in the pp -> p Lambda K+ reaction at 2.85 GeV
- quasi-bound state and the interaction: coupled-channel Faddeev calculations of the system
- The basic K nuclear cluster K- pp and its enhanced formation in the p + p -> K+ + X reaction
- Resonance energy of the barKNN-piYN system
- Variational calculations for K-few-nucleon systems
- Precision measurement of the x-ray energy in kaonic He
- S-Wave Scattering of Fermion Revisited
- A Novel UV Photon Detector with Resistive Electrodes
- Formation spectra of light kaonic nuclei by in-flight () reactions with chiral unitary amplitude
- ppK- bound states from Skyrmions