Cavity-enhanced optical frequency comb spectroscopy in the mid-infrared - application to trace detection of H2O2
arXiv:1202.1216 · doi:10.1007/s00340-012-5024-7
Abstract
We demonstrate the first cavity-enhanced optical frequency comb spectroscopy in the mid-infrared wavelength region and report the sensitive real-time trace detection of hydrogen peroxide in the presence of a large amount of water. The experimental apparatus is based on a mid-infrared optical parametric oscillator synchronously pumped by a high power Yb:fiber laser, a high finesse broadband cavity, and a fast-scanning Fourier transform spectrometer with autobalancing detection. The comb spectrum with a bandwidth of 200 nm centered around 3.75 μm is simultaneously coupled to the cavity and both degrees of freedom of the comb, i.e., the repetition rate and carrier envelope offset frequency, are locked to the cavity to ensure stable transmission. The autobalancing detection scheme reduces the intensity noise by a factor of 300, and a sensitivity of 5.4 {\times} 10^-9 cm^-1 Hz^-1/2 with a resolution of 800 MHz is achieved (corresponding to 6.9 {\times} 10^-11 cm^-1 Hz^-1/2 per spectral element for 6000 resolved elements). This yields a noise equivalent detection limit for hydrogen peroxide of 8 parts-per-billion (ppb); in the presence of 2.8% of water the detection limit is 130 ppb. Spectra of acetylene, methane and nitrous oxide at atmospheric pressure are also presented, and a line shape model is developed to simulate the experimental data.
submitted to special FLAIR 2011 issue of Appl. Phys. B
References in corpus (5)
- Coherent, multi-heterodyne spectroscopy using stabilized optical frequency combs
- Mid-Infrared Frequency Comb Fourier Transform Spectrometer
- Quantum-noise-limited optical frequency comb spectroscopy
- Cavity-enhanced direct frequency comb spectroscopy
- Sensitive multiplex spectroscopy in the molecular fingerprint 2.4 m region with a Cr^{2+}:ZnSe femtosecond laser
Cited by in corpus (37)
- Mid-infrared frequency combs
- Surpassing the Path-Limited Resolution of a Fourier Transform Spectrometer with Frequency Combs
- Continuous probe of cold complex molecules with infrared frequency comb spectroscopy
- Mid-infrared VIPA Spectrometer for Rapid and Broadband Trace Gas Detection
- Self-corrected chip-based dual-comb spectrometer
- Mid-Infrared ultra-high-Q resonators based on fluoride crystalline materials
- Optical Frequency Comb Fourier Transform Spectroscopy with Sub-Nominal Resolution - Principles and Implementation
- Coherent cavity-enhanced dual-comb spectroscopy
- Ultrafast extreme ultraviolet photoemission without space charge
- Optical frequency comb spectroscopy at 3-5.4 μm with a doubly resonant optical parametric oscillator
- Cavity-Enhanced Ultrafast Transient Absorption Spectroscopy
- Intracavity trace molecular detection with a broadband mid-IR frequency comb source
- Dual-comb cavity ring-down spectroscopy
- Mid-infrared frequency comb with 6.7 W average power based on difference frequency generation
- Analog FM free-space optical communication based on a mid-infrared quantum cascade laser frequency comb
- Noise-immune cavity-enhanced optical frequency comb spectroscopy: A sensitive technique for high-resolution broadband molecular detection
- Sub-Doppler optical-optical double-resonance spectroscopy using a cavity-enhanced frequency comb probe
- Comb-resolved spectroscopy with immersion grating in long-wave infrared
- An experimental water line list at 1950 K in the 6250 -- 6670 \cm\ region
- Continuous Vernier filtering of an optical frequency comb for broadband cavity-enhanced molecular spectroscopy
- Intensity Noise Optimization of a Mid-Infrared Frequency Comb Difference Frequency Generation Source
- Mid-infrared continuous-filtering Vernier spectroscopy using a doubly resonant optical parametric oscillator
- Quantitative modeling of complex molecular response in coherent cavity-enhanced dual-comb spectroscopy
- Broadband calibration-free cavity-enhanced complex refractive index spectroscopy using a frequency comb
- Frequency comb vernier spectroscopy in the near infrared
- Compact mode-locked Er-doped fiber laser for broadband cavity-enhanced spectroscopy
- Measurement and assignment of J = 5 to 9 rotational energy levels in the 9070-9370 cm range of methane using optical frequency comb double-resonance spectroscopy
- Widely tunable cavity-enhanced frequency combs
- Combined frequency comb and continuous wave cavity-enhanced optical-optical double-resonance spectrometer in the 1.7 m range
- Coherence analysis of tightly locked mid-infrared quantum cascade laser frequency combs
- Coherent Control of Mid-Infrared Frequency Comb by Optical Injection of Near-Infrared Light
- Signal line shapes of Fourier transform cavity-enhanced frequency modulation spectroscopy with optical frequency combs
- Assignment of collision-induced four-level double-resonance transitions in the 3 spectral region of methane
- Ultra-sensitive multi-species spectroscopic breath analysis for real-time health monitoring and diagnostics
- Measurement and assignment of E-symmetry states in the 6010-6110 cm and 8940-9150 cm ranges of methane using optical frequency comb double-resonance spectroscopy
- Optical frequency comb double-resonance spectroscopy of the 9030-9175 cm states of ethylene
- Mid-infrared monocrystalline interference coatings with excess optical loss below 10 ppm