Continuous probe of cold complex molecules with infrared frequency comb spectroscopy
arXiv:1601.07845 · doi:10.1038/nature17440
Abstract
Cavity-enhanced frequency comb spectroscopy for molecule detection in the mid-infrared powerfully combines high resolution, high sensitivity, and broad spectral coverage. However, this technique, and essentially all spectroscopic methods, is limited in application to relatively small, simple molecules. Here we integrate comb spectroscopy with continuous, cold samples of molecules produced via buffer gas cooling, thus enabling the study of significantly more complex molecules. We report simultaneous gains in resolution, sensitivity, and bandwidth and demonstrate this combined capability with the first rotationally resolved direct absorption spectra in the CH stretch region of several complex molecules. These include nitromethane (CHNO), a model system that presents challenging questions to the understanding of large amplitude vibrational motion, as well as several large organic molecules with fundamental spectroscopic and astrochemical relevance, including naphthalene (CH), adamantane (CH), and hexamethylenetetramine (CNH). This general spectroscopic tool has the potential to significantly impact the field of molecular spectroscopy, simultaneously improving efficiency, spectral resolution, and specificity by orders of magnitude. This realization could open up new molecular species and new kinetics for precise investigations, including the study of complex molecules, weakly bound clusters, and cold chemistry.
References in corpus (6)
- Phase-stabilized, 1.5-W frequency comb at 2.8 to 4.8 micron
- Mid-Infrared Frequency Comb Fourier Transform Spectrometer
- Quantum-noise-limited optical frequency comb spectroscopy
- Surpassing the Path-Limited Resolution of a Fourier Transform Spectrometer with Frequency Combs
- Cavity-enhanced optical frequency comb spectroscopy in the mid-infrared - application to trace detection of H2O2
- Cavity-enhanced direct frequency comb spectroscopy
Cited by in corpus (47)
- Frequency comb spectroscopy
- Turning a molecule into a coherent two-level quantum system
- Enantiomer-Specific State Transfer of Chiral Molecules
- A phase-stable dual-comb interferometer
- Quantum state resolution of the C fullerene
- Toward a determination of the proton-electron mass ratio from the Lamb-dip measurement of HD
- Compact, all-PM fiber integrated and alignment-free ultrafast Yb:fiber NALM laser with sub-femtosecond timing jitter
- Rovibrational Polaritons in Gas-Phase Methane
- mid-infrared frequency comb generation and stabilization with few-cycle pulses
- Doppler-free Fourier transform spectroscopy
- High-resolution and gapless dual comb spectroscopy with current-tuned quantum cascade lasers
- Nonlinear silicon waveguides generating broadband, spectrally engineered frequency combs spanning 2.0-8.5 um
- Molecular near-infrared transitions determined with sub-kHz accuracy
- Sensitive and broadband measurement of dispersion in a cavity using a Fourier transform spectrometer with kHz resolution
- Microresonator-based high-resolution gas spectroscopy
- Dual-comb cavity ring-down spectroscopy
- Long-lived complexes and signatures of chaos in ultracold K2+Rb collisions
- Three Photon Absorption in Optical Parametric Oscillators Based on OP-GaAs
- Phase-stabilized 100 mW frequency comb near 10 μm
- Ab initio effective rotational and rovibrational Hamiltonians for non-rigid systems via curvilinear second order vibrational Møller-Plesset perturbation theory
- High Sensitivity Microwave Spectroscopy in a Cryogenic Buffer Gas Cell
- Data availability and requirements relevant for the Ariel space mission and other exoplanet atmosphere applications
- High-resolution mid-infrared spectroscopy of buffer-gas-cooled methyltrioxorhenium molecules
- A versatile platform for gas-phase molecular polaritonics
- Bending modes metrology in the 14-15 m region
- Molecular Collisions: from Near-cold to Ultra-cold
- Comb-resolved spectroscopy with immersion grating in long-wave infrared
- Broadband calibration-free cavity-enhanced complex refractive index spectroscopy using a frequency comb
- Quantitative modeling of complex molecular response in coherent cavity-enhanced dual-comb spectroscopy
- Mid-infrared continuous-filtering Vernier spectroscopy using a doubly resonant optical parametric oscillator
- Optical frequency comb Faraday rotation spectroscopy
- Cavity-Enhanced Vernier Spectroscopy with a Chip-Scale Mid-Infrared Frequency Comb
- Simulation of Cryogenic Buffer Gas Beams
- Collision-induced C_60 rovibrational relaxation probed by state-resolved nonlinear spectroscopy
- Nonlinear Quantum Behavior of Ultrashort-Pulse Optical Parametric Oscillators
- OD + CO -> D + CO2 Branching Kinetics Probed with Time-Resolved Frequency Comb Spectroscopy
- Production of carbon clusters to with a cryogenic buffer-gas beam source
- Laser spectroscopy of cold molecules
- Spectral analyses of trans- and cis-DOCO transients via comb spectroscopy
- Fast and High-Yield Loading of a D MOT of Potassium from a Cryogenic Buffer Gas Beam
- Dynamics of a buffer-gas-loaded, deep optical trap for molecules
- Broadband Cavity-Enhanced Kerr Comb Spectroscopy on Chip
- Low- transitions in band of buffer-gas-cooled CaOH
- Measurement of Doppler effects in cryogenic buffer-gas cell
- Versatile optical frequency combs based on multi-seeded femtosecond optical parametric generation
- Quantum Reactive Scattering of Ultracold Atoms and Molecules: Universality and Chaotic Dynamics
- Long-wave mid-infrared cavity-enhanced frequency comb spectroscopy of cold, complex molecules