Combined frequency comb and continuous wave cavity-enhanced optical-optical double-resonance spectrometer in the 1.7 m range
arXiv:2506.17669 · doi:10.1364/OE.571448
Abstract
We present an optical-optical double-resonance (OODR) spectrometer based on a 3.3 m continuous wave pump and two cavity-enhanced probes: a frequency comb tunable in the 1.64 - 1.8 m range, and a comb-referenced continuous wave (CW) laser tunable in the 1.6 - 1.75 m range. The comb probe provides broad spectral coverage (bandwidth up to 7 THz) for simultaneous detection of many sub-Doppler OODR transitions with sub-MHz line position accuracy, while the CW probe allows targeting individual transitions with kHz accuracy and higher signal-to-noise ratio in shorter time. Using the pump stabilized to the frequency of the R(0) transition in the band of methane and the comb probe covering the 5550 to 6070 cm interval, we detect 37 ladder-type transitions in the 3 band region and 6 V-type transitions in the 2 band region and assign them using available theoretical predictions. Using the CW probe, we measure selected ladder- and V-type transitions with much higher precision. We also detect Lamb dips in the R(0)- R(3) transitions of the 2 band and report their center frequencies with kHz level accuracy. The synergy effects of the comb- and CW-OODR open new possibilities in precision spectroscopy of levels that cannot be reached from the ground state.
References in corpus (13)
- An accurate, extensive, and practical line list of methane for the HITEMP database
- Quantum-noise-limited optical frequency comb spectroscopy
- Surpassing the Path-Limited Resolution of a Fourier Transform Spectrometer with Frequency Combs
- Cavity-enhanced optical frequency comb spectroscopy in the mid-infrared - application to trace detection of H2O2
- Optical Frequency Comb Fourier Transform Spectroscopy with Sub-Nominal Resolution - Principles and Implementation
- Baseline-free Quantitative Absorption Spectroscopy Based on Cepstral Analysis
- High-power frequency comb source tunable from 2.7 to 4.2 μm based on difference frequency generation pumped by an Yb-doped fiber laser
- Sub-Doppler Double-Resonance Spectroscopy of Methane Using a Frequency Comb Probe
- Sub-Doppler optical-optical double-resonance spectroscopy using a cavity-enhanced frequency comb probe
- Double resonant absorption measurement of acetylene symmetric vibrational states probed with cavity ring down spectroscopy
- Measurement and assignment of J = 5 to 9 rotational energy levels in the 9070-9370 cm range of methane using optical frequency comb double-resonance spectroscopy
- Polarization-dependent Intensity Ratios in Double Resonance Spectroscopy
- Precision frequency comb spectroscopy of the NO, NNO, NNO, and NO isotopocules in the 3300-3550 cm range
Cited by in corpus (4)
- Assignment of collision-induced four-level double-resonance transitions in the 3 spectral region of methane
- Measurement and assignment of E-symmetry states in the 6010-6110 cm and 8940-9150 cm ranges of methane using optical frequency comb double-resonance spectroscopy
- Theory of Lineshapes in Optical-Optical Double Resonance Spectroscopy
- Optical frequency comb double-resonance spectroscopy of the 9030-9175 cm states of ethylene