Position Reconstruction in a Dual Phase Xenon Scintillation Detector
arXiv:1112.1481 · doi:10.1109/TNS.2012.2221742
Abstract
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the performance of the ZEPLIN-III dark matter detector was studied for 122 keV gamma-rays. For the inner part of the detector (R<100 mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the horizontal plane for primary and secondary scintillation, respectively. An energy resolution of 8.1% FWHM was achieved at that energy. The possibility of using this technique for improving performance and reducing cost of scintillation cameras for medical applications is currently under study.
arXiv comment8 pages, 7 figures, in the Conference Record of IEEE NSS 2011, accepted for publication in IEEE Trans. on Nuc. Sci
References in corpus (8)
- Liquid Xenon Detectors for Particle Physics and Astrophysics
- Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
- WIMP-nucleon cross-section results from the second science run of ZEPLIN-III
- Correlated Fluctuations between Luminescence and Ionization in Liquid Xenon
- The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning
- Limits on the spin-dependent WIMP-nucleon cross-sections from the first science run of the ZEPLIN-III experiment
- Limits on inelastic dark matter from ZEPLIN-III
- ZE3RA: The ZEPLIN-III Reduction and Analysis Package
Cited by in corpus (34)
- First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
- Dark Matter Results from First 98.7-day Data of PandaX-II Experiment
- Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data
- The Large Underground Xenon (LUX) Experiment
- Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
- Liquid noble gas detectors for low energy particle physics
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- WIMP-nucleon cross-section results from the second science run of ZEPLIN-III
- Technical Results from the Surface Run of the LUX Dark Matter Experiment
- ANTS2 package: simulation and experimental data processing for Anger camera type detectors
- First ground-level laboratory test of the two-phase xenon emission detector RED-100
- Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers
- Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
- SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range
- Proposed low-energy absolute calibration of nuclear recoils in a dual-phase noble element TPC using D-D neutron scattering kinematics
- Measurement of Charge and Light Yields for Xe L-Shell Electron Captures in Liquid Xenon
- Experimental study of ionization yield of liquid xenon for electron recoils in the energy range 2.8 - 80 keV
- Machine Learning Accelerated Likelihood-Free Event Reconstruction in Dark Matter Direct Detection
- Iterative reconstruction of the detector response for medical gamma cameras
- Horizontal Position Reconstruction in PandaX-II
- Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of Xe
- SiPM-based neutron Anger camera with auto-calibration capabilities
- Coherent Scattering Investigations at the Spallation Neutron Source: a Snowmass White Paper
- Iterative reconstruction of SiPM light response functions in a square-shaped compact gamma camera
- Two-phase xenon emission detector with electron multiplier and optical readout by multipixel avalanche Geiger photodiodes
- Development and Characterization of a Multi-APD Xenon Electroluminescence TPC
- Detection and Calibration of Low-Energy Nuclear Recoils for Dark Matter and Neutrino Scattering Experiments
- Domain-informed neural networks for interaction localization within astroparticle experiments
- Performance data from the ZEPLIN-III second science run
- B-spline parameterization of spatial response in a monolithic scintillation camera
- Calibration and characterization of the RED-100 detector at the Kalinin nuclear power plant
- A Noble Gas Detector with Electroluminescence Readout based on an Array of APDs
- Position reconstruction and surface background model for the PandaX-4T detector
- Study of light detection and sensitivity for a ton-scale liquid xenon dark matter detector