Position Reconstruction in a Dual Phase Xenon Scintillation Detector
arXiv:1112.1481 · doi:10.1109/TNS.2012.2221742
Abstract
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the performance of the ZEPLIN-III dark matter detector was studied for 122 keV gamma-rays. For the inner part of the detector (R<100 mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the horizontal plane for primary and secondary scintillation, respectively. An energy resolution of 8.1% FWHM was achieved at that energy. The possibility of using this technique for improving performance and reducing cost of scintillation cameras for medical applications is currently under study.
8 pages, 7 figures, in the Conference Record of IEEE NSS 2011, accepted for publication in IEEE Trans. on Nuc. Sci
References in corpus (4)
- Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
- WIMP-nucleon cross-section results from the second science run of ZEPLIN-III
- The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning
- Limits on the spin-dependent WIMP-nucleon cross-sections from the first science run of the ZEPLIN-III experiment
Cited by in corpus (34)
- First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
- Dark Matter Results from First 98.7-day Data of PandaX-II Experiment
- Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data
- The Large Underground Xenon (LUX) Experiment
- Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
- Liquid noble gas detectors for low energy particle physics
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- WIMP-nucleon cross-section results from the second science run of ZEPLIN-III
- Technical Results from the Surface Run of the LUX Dark Matter Experiment
- ANTS2 package: simulation and experimental data processing for Anger camera type detectors
- First ground-level laboratory test of the two-phase xenon emission detector RED-100
- Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers
- Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
- SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range
- Proposed low-energy absolute calibration of nuclear recoils in a dual-phase noble element TPC using D-D neutron scattering kinematics
- Measurement of Charge and Light Yields for Xe L-Shell Electron Captures in Liquid Xenon
- Experimental study of ionization yield of liquid xenon for electron recoils in the energy range 2.8 - 80 keV
- Machine Learning Accelerated Likelihood-Free Event Reconstruction in Dark Matter Direct Detection
- Iterative reconstruction of the detector response for medical gamma cameras
- Horizontal Position Reconstruction in PandaX-II
- Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of Xe
- SiPM-based neutron Anger camera with auto-calibration capabilities
- Coherent Scattering Investigations at the Spallation Neutron Source: a Snowmass White Paper
- Iterative reconstruction of SiPM light response functions in a square-shaped compact gamma camera
- Two-phase xenon emission detector with electron multiplier and optical readout by multipixel avalanche Geiger photodiodes
- Development and Characterization of a Multi-APD Xenon Electroluminescence TPC
- Detection and Calibration of Low-Energy Nuclear Recoils for Dark Matter and Neutrino Scattering Experiments
- Domain-informed neural networks for interaction localization within astroparticle experiments
- Performance data from the ZEPLIN-III second science run
- B-spline parameterization of spatial response in a monolithic scintillation camera
- Calibration and characterization of the RED-100 detector at the Kalinin nuclear power plant
- A Noble Gas Detector with Electroluminescence Readout based on an Array of APDs
- Position reconstruction and surface background model for the PandaX-4T detector
- Study of light detection and sensitivity for a ton-scale liquid xenon dark matter detector