The CMS Magnetic Field Map Performance
arXiv:1110.0607 · doi:10.1109/TASC.2010.2041200
Abstract
The Compact Muon Solenoid (CMS) is a general-purpose detector designed to run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its distinctive featuresinclude a 4 T superconducting solenoid with 6 m diameter by 12.5 m long free bore, enclosed inside a 10000-ton return yoke made of construction steel. Accurate characterization of the magnetic field everywhere in the CMS detector is required. During two major tests of the CMS magnet the magnetic flux density was measured inside the coil in a cylinder of 3.448 m diameter and 7 m length with a specially designed field-mapping pneumatic machine as well as in 140 discrete regions of the CMS yoke with NMR probes, 3-D Hall sensors and flux-loops. A TOSCA 3-D model of the CMS magnet has been developed to describe the magnetic field everywhere outside the tracking volume measured with the field-mapping machine. A volume based representation of the magnetic field is used to provide the CMS simulation and reconstruction software with the magnetic field values. The value of the field at a given point of a volume is obtained by interpolation from a regular grid of values resulting from a TOSCA calculation or, when available, from a parameterization. The results of the measurements and calculations are presented, compared and discussed.
4 pages, 4 figures, 17 references
References in corpus (7)
- Precise Mapping of the Magnetic Field in the CMS Barrel Yoke using Cosmic Rays
- Measurement of the CMS Magnetic Field
- 3D Magnetic Analysis of the CMS Magnet
- The CMS Magnetic Field Map Performance
- Developing the Technique of Measurements of Magnetic Field in the CMS Steel Yoke Elements With Flux-Loops and Hall Probes
- Analysis of Eddy Current Distributions in the CMS Magnet Yoke During the Solenoid Discharge
- On a Possibility to Measure the Magnetic Field Inside the CMS Yoke Elements
Cited by in corpus (9)
- The CMS Magnetic Field Map Performance
- Modeling Magnetic Fields with Helical Solutions to Laplace's Equation
- Measuring the Magnetic Flux Density in the CMS Steel Yoke
- Design and Description of the CMS Magnetic System Model
- Using the Standard Linear Ramps of the CMS Superconducting Magnet for Measuring the Magnetic Flux Density in the Steel Flux Return Yoke
- Validation of the CMS Magnetic Field Map
- The CMS Magnetic Field Measuring and Monitoring Systems
- Flux Loop Measurements of the Magnetic Flux Density in the CMS Magnet Yoke
- Measuring the Magnetic Flux Density with Flux Loops and Hall Probes in the CMS Magnet Flux Return Yoke