Measuring the Magnetic Flux Density in the CMS Steel Yoke
arXiv:1212.1657 · doi:10.1007/s10948-012-1967-5
Abstract
The Compact Muon Solenoid (CMS) is a general purpose detector, designed to run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its distinctive features include a 4 T superconducting solenoid with 6-m-diameter by 12.5-m-length free bore, enclosed inside a 10000-ton return yoke made of construction steel. The return yoke consists of five dodecagonal three-layered barrel wheels and four end-cap disks at each end comprised of steel blocks up to 620 mm thick, which serve as the absorber plates of the muon detection system. Accurate characterization of the magnetic field everywhere in the CMS detector is required. To measure the field in and around the steel, a system of 22 flux-loops and 82 3-D Hall sensors is installed on the return yoke blocks. Fast discharges of the solenoid (190 s time-constant) made during the CMS magnet surface commissioning test at the solenoid central fields of 2.64, 3.16, 3.68 and 4.01 T were used to induce voltages in the flux-loops. The voltages are measured on-line and integrated off-line to obtain the magnetic flux in the steel yoke close to the muon chambers at full excitations of the solenoid. The 3-D Hall sensors installed on the steel-air interfaces give supplementary information on the components of magnetic field and permit to estimate the remanent field in steel to be added to the magnetic flux density obtained by the voltages integration. A TOSCA 3-D model of the CMS magnet is developed to describe the magnetic field everywhere outside the tracking volume measured with the field-mapping machine. The results of the measurements and calculations are presented, compared and discussed.
9 pages, 7 figures, 16 references, presented at the III International Conference on Superconductivity and Magnetism (ICSM-2012), Kumburgaz, Istanbul, Turkey, 29 April - 4 May 2012
References in corpus (5)
- Measurement of the CMS Magnetic Field
- 3D Magnetic Analysis of the CMS Magnet
- The CMS Magnetic Field Map Performance
- Developing the Technique of Measurements of Magnetic Field in the CMS Steel Yoke Elements With Flux-Loops and Hall Probes
- Analysis of Eddy Current Distributions in the CMS Magnet Yoke During the Solenoid Discharge
Cited by in corpus (7)
- Design and Description of the CMS Magnetic System Model
- Using the Standard Linear Ramps of the CMS Superconducting Magnet for Measuring the Magnetic Flux Density in the Steel Flux Return Yoke
- Validation of the CMS Magnetic Field Map
- The CMS Magnetic Field Measuring and Monitoring Systems
- Flux Loop Measurements of the Magnetic Flux Density in the CMS Magnet Yoke
- Measuring the Magnetic Flux Density with Flux Loops and Hall Probes in the CMS Magnet Flux Return Yoke
- Analysis of Measurements of the Magnetic Flux Density in Steel Blocks of the Compact Muon Solenoid Magnet Yoke with Solenoid Coil Fast Discharges