126 citations · 499 across the 9 of their papers we have counts for
9 papers · 1 filter
Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector
The LUX Collaboration, D. S. Akerib, S. Alsum +90
Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection cham…
Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
D. S. Akerib, S. Alsum, H. M. Araújo +95
The LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sectio…
Ultra-Low Energy Calibration of LUX Detector using Xe Electron Capture
LUX Collaboration, D. S. Akerib, S. Alsum +91
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 3…
Kr calibration of the 2013 LUX dark matter search
LUX Collaboration, D. S. Akerib, S. Alsum +91
LUX was the first dark matter experiment to use a Kr calibration source. In this paper we describe the source preparation and injection. We also present several $^…
Signal yields, energy resolution, and recombination fluctuations in liquid xenon
D. S. Akerib, S. Alsum, H. M. Araújo +98
This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Undergrou…
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
LUX Collaboration, D. S. Akerib, S. Alsum +104
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota…
Tritium calibration of the LUX dark matter experiment
LUX Collaboration, D. S. Akerib, H. M. Araújo +98
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the…
FPGA-based Trigger System for the LUX Dark Matter Experiment
D. S. Akerib, H. M. Araujo, X. Bai +100
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils resulting from interactions with dark matter particles. Signals from the detector a…
LUX-ZEPLIN (LZ) Conceptual Design Report
The LZ Collaboration, D. S. Akerib, C. W. Akerlof +192
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the p…