activity
20142026
most citedDark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment

915 citations · 3.8k across the 64 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

11 papers · 1 filter

physics.ins-det2025

Development of a dual-phase xenon time projection chamber prototype for the RELICS experiment

Lingfeng Xie, Jiajun Liu, Yifei Zhao +50

The RELICS (REactor neutrino LIquid xenon Coherent elastic Scattering) experiment aims to detect coherent elastic neutrino-nucleus scattering from reactor antineutrinos using a dua…

physics.ins-det2025★ 1 cited

Preparation and measurement of an Ar source for liquid xenon detector calibration

Xu-Nan Guo, Chang Cai, Fei Gao +8

We present the preparation and measurement of the radioactive isotope , which was produced using thermal neutrons from a reactor, as a calibration source for liquid xe…

physics.ins-det2025★ 1 cited

Position reconstruction and surface background model for the PandaX-4T detector

Zhicheng Qian, Linhui Gu, Chen Cheng +100

We report the position reconstruction methods and surface background model for the PandaX-4T dark matter direct search experiment. This work develops two position reconstruction al…

physics.ins-det2024

Characterization of a gaseous time projection chamber with an internal \ce{^{37}Ar} source

Wenming Zhang, Yuanchun Liu, Ke Han +3

We report on a novel calibration method of gaseous detectors using an internal \ce{^{37}Ar} source. The \ce{^{37}Ar} is a fast-decaying and low-energy calibration source that provi…

physics.ins-det2024★ 20 cited

Signal Response Model in PandaX-4T

Yunyang Luo, Zihao Bo, Shibo Zhang +88

PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of li…

physics.ins-det2022

Transition edge sensor based detector: from X-ray to -ray

Shuo Zhang, Jing-Kai Xia, Tao Sun +15

The Transition Edge Sensor is extremely sensitive to the change of temperature, combined with the high-Z metal of a certain thickness, it can realize the high energy resolution mea…

physics.ins-det2021★ 34 cited

Low Radioactive Material Screening and Background Control for the PandaX-4T Experiment

Zhicheng Qian, Lin Si, Abdusalam Abdukerim +76

PandaX-4T is a ton-scale dark matter direct detection experiment using a dual-phase TPC technique at the China Jinping Underground Laboratory. Various ultra-low background technolo…

physics.ins-det2021★ 17 cited

Determination of responses of liquid xenon to low energy electron and nuclear recoils using the PandaX-II detector

Binbin Yan, Abdusalam Abdukerim, Wei Chen +63

We report a systematic determination of the responses of PandaX-II, a dual phase xenon time projection chamber detector, to low energy recoils. The electron recoil (ER) and nuclear…

physics.ins-det2020★ 16 cited

Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources

Wenbo Ma, Abdusalam Abdukerim, Zihao Bo +65

We have developed a low-energy electron recoil (ER) calibration method with Rn for the PandaX-II detector. Rn, emanated from natural thorium compounds, was fed into…

physics.ins-det2018★ 161 cited

Dark matter direct search sensitivity of the PandaX-4T experiment

Hongguang Zhang, Abdusalam Abdukerim, Xun Chen +57

The PandaX-4T experiment, a four-ton scale dark matter direct detection experiment, is being planned at the China Jinping Underground Laboratory. In this paper we present a simulat…

physics.ins-det2014★ 15 cited

PandaX: A Liquid Xenon Dark Matter Experiment at CJPL

X. G. Cao, X. Chen, Y. H. Chen +47

PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and Xe double-beta decay search. It is located in the Jinpi…