915 citations · 3.8k across the 64 of their papers we have counts for
11 papers · 1 filter
Development of a dual-phase xenon time projection chamber prototype for the RELICS experiment
Lingfeng Xie, Jiajun Liu, Yifei Zhao +50
The RELICS (REactor neutrino LIquid xenon Coherent elastic Scattering) experiment aims to detect coherent elastic neutrino-nucleus scattering from reactor antineutrinos using a dua…
Preparation and measurement of an Ar source for liquid xenon detector calibration
Xu-Nan Guo, Chang Cai, Fei Gao +8
We present the preparation and measurement of the radioactive isotope , which was produced using thermal neutrons from a reactor, as a calibration source for liquid xe…
Position reconstruction and surface background model for the PandaX-4T detector
Zhicheng Qian, Linhui Gu, Chen Cheng +100
We report the position reconstruction methods and surface background model for the PandaX-4T dark matter direct search experiment. This work develops two position reconstruction al…
Characterization of a gaseous time projection chamber with an internal \ce{^{37}Ar} source
Wenming Zhang, Yuanchun Liu, Ke Han +3
We report on a novel calibration method of gaseous detectors using an internal \ce{^{37}Ar} source. The \ce{^{37}Ar} is a fast-decaying and low-energy calibration source that provi…
Signal Response Model in PandaX-4T
Yunyang Luo, Zihao Bo, Shibo Zhang +88
PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of li…
Transition edge sensor based detector: from X-ray to -ray
Shuo Zhang, Jing-Kai Xia, Tao Sun +15
The Transition Edge Sensor is extremely sensitive to the change of temperature, combined with the high-Z metal of a certain thickness, it can realize the high energy resolution mea…
Low Radioactive Material Screening and Background Control for the PandaX-4T Experiment
Zhicheng Qian, Lin Si, Abdusalam Abdukerim +76
PandaX-4T is a ton-scale dark matter direct detection experiment using a dual-phase TPC technique at the China Jinping Underground Laboratory. Various ultra-low background technolo…
Determination of responses of liquid xenon to low energy electron and nuclear recoils using the PandaX-II detector
Binbin Yan, Abdusalam Abdukerim, Wei Chen +63
We report a systematic determination of the responses of PandaX-II, a dual phase xenon time projection chamber detector, to low energy recoils. The electron recoil (ER) and nuclear…
Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources
Wenbo Ma, Abdusalam Abdukerim, Zihao Bo +65
We have developed a low-energy electron recoil (ER) calibration method with Rn for the PandaX-II detector. Rn, emanated from natural thorium compounds, was fed into…
Dark matter direct search sensitivity of the PandaX-4T experiment
Hongguang Zhang, Abdusalam Abdukerim, Xun Chen +57
The PandaX-4T experiment, a four-ton scale dark matter direct detection experiment, is being planned at the China Jinping Underground Laboratory. In this paper we present a simulat…
PandaX: A Liquid Xenon Dark Matter Experiment at CJPL
X. G. Cao, X. Chen, Y. H. Chen +47
PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and Xe double-beta decay search. It is located in the Jinpi…