30 citations · 91 across the 8 of their papers we have counts for
8 papers
Light-yield response of liquid scintillators using 2--6 MeV tagged neutrons
N. Mauritzson, K. G. Fissum, J. R. M. Annand +10
Knowledge of the neutron light-yield response is crucial to the understanding of scintillator-based neutron detectors. In this work, neutrons from 2--6 MeV have been used to study…
Response of a Li-glass/multi-anode photomultiplier detector to collimated thermal-neutron beams
E. Rofors, N. Mauritzson, H. Perrey +22
The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimat…
Response of a Li-glass/multi-anode photomultiplier detector to focused proton and deuteron beams
E. Rofors, J. Pallon, R. Al Jebali +26
The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across th…
Response of a Li-glass/multi-anode photomultiplier detector to -particles from Am
E. Rofors, H. Perrey, R. Al Jebali +18
The response of a position-sensitive Li-glass scintillator detector to -particles from a collimated Am source scanned across the face of the detector has been measured.…
The neutron tagging facility at Lund University
F. Messi, H. Perrey, K. Fissum +27
Over the last decades, the field of thermal neutron detection has overwhelmingly employed He-3-based technologies. The He-3 crisis together with the forthcoming establishment of th…
A comparison of untagged gamma-ray and tagged-neutron yields from 241AmBe and 238PuBe sources
Julius Scherzinger, Ramsey Al Jebali, John Annand +7
Untagged gamma-ray and tagged-neutron yields from 241AmBe and 238PuBe mixed-field sources have been measured. Gamma-ray spectroscopy measurements from 1 - 5 MeV were performed in a…
The light-yield response of a NE-213 liquid-scintillator detector measured using 2 -- 6 MeV tagged neutrons
J. Scherzinger, R. Al Jebali, J. R. M. Annand +8
The response of a NE-213 liquid-scintillator detector has been measured using tagged neutrons from 2--6 MeV originating from an Am/Be neutron source. The neutron energies were dete…
Overcoming High Energy Backgrounds at Pulsed Spallation Sources
Nataliia Cherkashyna, Richard J. Hall-Wilton, Douglas D. DiJulio +18
Instrument backgrounds at neutron scattering facilities directly affect the quality and the efficiency of the scientific measurements that users perform. Part of the background at…