Response of a Li-glass/multi-anode photomultiplier detector to focused proton and deuteron beams
arXiv:2005.08675 · doi:10.1016/j.nima.2020.164604
Abstract
The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across the detector in 0.5 mm horizontal and vertical steps perpendicular to the beams. Scintillation light was registered using an 8 by 8 pixel multi-anode photomultiplier tube. The signal amplitudes were recorded for each pixel on an event-by-event basis. Several pixels generally registered considerable signals at each beam location. The number of pixels above set thresholds were investigated, with the optimization of the single-hit efficiency over the largest possible area as the goal. For both beams, at a threshold of ~50% of the mean of the full-deposition peak, ~80% of the events were registered in a single pixel, resulting in an effective position resolution of ~5 mm in X and Y.
arXiv comment22 pages, 8 figures, to be submitted to Nucl. Instr. and Meth. in Phys. Res. A
References in corpus (9)
- Studies of Proximity Focusing RICH with an aerogel radiator using Flat-panel multi-anode PMTs (Hamamatsu H8500)
- Concept for a Time-of-Flight Small Angle Neutron Scattering Instrument at the European Spallation Source
- Characterization of the Hamamatsu H12700A-03 and R12699-03 multi-anode photomultiplier tubes
- Architecture of the data aggregation and streaming system for the European Spallation Source neutron instrument suite
- Software-based data acquisition and processing for neutron detectors at European Spallation Source - early experience from four detector designs
- Cumulative Reports of the SoNDe Project July 2017
- Response of a Li-glass/multi-anode photomultiplier detector to -particles from Am
- Determining the 6Li Doped Side of a Glass Scintillator for Ultra Cold Neutrons
- Achieveing reliable UDP transmission at 10 Gb/s using BSD socket for data acquisition systems