65 citations · 162 across the 11 of their papers we have counts for
10 papers · 1 filter
Light-yield response of liquid scintillators using 2--6 MeV tagged neutrons
N. Mauritzson, K. G. Fissum, J. R. M. Annand +10
Knowledge of the neutron light-yield response is crucial to the understanding of scintillator-based neutron detectors. In this work, neutrons from 2--6 MeV have been used to study…
Technique for the measurement of intrinsic pulse-shape discrimination for organic scintillators using tagged neutrons
N. Mauritzson, K. G. Fissum, J. R. M. Annand +10
Fast-neutron/gamma-ray pulse-shape discrimination has been performed for the organic liquid scintillators NE 213A and EJ 305 using a time-of-flight based neutron-tagging technique…
Geant4-based calibration of an organic liquid scintillator
N. Mauritzson, K. G. Fissum, H. Perrey +8
A light-yield calibration of an NE 213A organic liquid scintillator detector has been performed using both monoenergetic and polyenergetic gamma-ray sources. Scintillation light wa…
Simulation of the Response of the Solid State Neutron Detector for the European Spallation Source
L. Boyd, E. Rofors, J. R. M. Annand +10
The characteristics of the Solid-state Neutron Detector, under development for neutron-scattering measurements at the European Spallation Source, have been simulated with a Geant4-…
Response of a Li-glass/multi-anode photomultiplier detector to collimated thermal-neutron beams
E. Rofors, N. Mauritzson, H. Perrey +22
The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimat…
Response of a Li-glass/multi-anode photomultiplier detector to focused proton and deuteron beams
E. Rofors, J. Pallon, R. Al Jebali +26
The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across th…
Response of a Li-glass/multi-anode photomultiplier detector to -particles from Am
E. Rofors, H. Perrey, R. Al Jebali +18
The response of a position-sensitive Li-glass scintillator detector to -particles from a collimated Am source scanned across the face of the detector has been measured.…
The neutron tagging facility at Lund University
F. Messi, H. Perrey, K. Fissum +27
Over the last decades, the field of thermal neutron detection has overwhelmingly employed He-3-based technologies. The He-3 crisis together with the forthcoming establishment of th…
A Polyethylene-B4C based concrete for enhanced neutron shielding at neutron research facilities
D. D. DiJulio, C. P. Cooper-Jensen, H. Perrey +4
We present the development of a specialized concrete for neutron shielding at neutron research facilities, based on the addition of hydrogen atoms in the form of polyethylene and a…
A comparison of untagged gamma-ray and tagged-neutron yields from 241AmBe and 238PuBe sources
Julius Scherzinger, Ramsey Al Jebali, John Annand +7
Untagged gamma-ray and tagged-neutron yields from 241AmBe and 238PuBe mixed-field sources have been measured. Gamma-ray spectroscopy measurements from 1 - 5 MeV were performed in a…