activity
20042023
most citedHigh-precision mass measurements of nickel, copper, and gallium isotopes and the purported shell closure at N=40

142 citations · 568 across the 27 of their papers we have counts for

collaborators

27 papers

nucl-ex2023★ 11 cited

Search for a neutron dark decay in He

M. Le Joubioux, H. Savajols, W. Mittig +24

Neutron dark decays have been suggested as a solution to the discrepancy between bottle and beam experiments, providing a dark matter candidate that can be searched for in halo nuc…

nucl-ex2023★ 10 cited

High-precision Penning-trap mass measurements of Cd and In isotopes at JYFLTRAP remove the fluctuations in the two-neutron separation energies

A. Jaries, M. Stryjczyk, A. Kankainen +23

We report on the first direct mass measurements of the Cd and In isotopes performed at the Ion Guide Isotope Separator On-Line facility using the JYFLTRAP d…

nucl-ex2023★ 9 cited

High-precision measurements of low-lying isomeric states in In with JYFLTRAP double Penning trap

D. A. Nesterenko, J. Ruotsalainen, M. Stryjczyk +26

Neutron-rich In isotopes have been studied utilizing the double Penning trap mass spectrometer JYFLTRAP at the IGISOL facility. Using the phase-imaging ion-cyclotron-re…

nucl-ex2022★ 5 cited

High-resolution laser system for the S3-Low Energy Branch

Jekabs Romans, Anjali Ajayakumar, Martial Authier +39

In this paper we present the first high-resolution laser spectroscopy results obtained at the GISELE laser laboratory of the GANIL-SPIRAL2 facility, in preparation for the first ex…

nucl-ex2022★ 8 cited

Direct determination of the excitation energy of quasi-stable isomer Ta

D. A. Nesterenko, K. Blaum, P. Delahaye +11

Ta is a naturally abundant quasi-stable nuclide and the longest-lived nuclear isomer known to date. It is of interest for, among others, the search for dark matter, for th…

physics.acc-ph2020★ 3 cited

The spiral1 charge breeder: key points for a performant 1+ beam injection

L. Maunoury, O. Kamalou, J. F. Cam +6

The SPIRAL1 charge breeder is now under operation. Radioactive beam has already been delivered [1] to Physicist for performing experiment. Although charge breeding efficiencies dem…

physics.ins-det2020★ 3 cited

Geometry optimisation of a transparent axisymmetric ion trap for the MORA project

M. Benali, G. Quéméner, P. Delahaye +3

In the frame of the project MORA (Matter's Origin from the Radio Activity of trapped and oriented ions), a transparent axially symmetric radio-frequency ion trap (MORATrap) was des…

physics.acc-ph2019★ 10 cited

New exotic beams from the SPIRAL 1 upgrade

P. Delahaye, M. Dubois, L. Maunoury +21

Since 2001, the SPIRAL 1 facility has been one of the pioneering facilities in ISOL techniques for reaccelerating radioactive ion beams: the fragmentation of the heavy ion beams of…

physics.ins-det2018★ 17 cited

The MORA project

P. Delahaye, E. Liénard, I. Moore +25

The MORA (Matter's Origin from the RadioActivity of trapped and oriented ions) project aims at measuring with unprecedented precision the D correlation in the nuclear beta decay of…

physics.ins-det2018★ 7 cited

The open LPC Paul trap for precision measurements in beta decay

P. Delahaye, G. Ban, M. Benali +14

The LPCTrap experiment uses an open Paul trap which was built to enable precision measurements in the beta decay of radioactive ions. The initial goal was the precise measurement o…

physics.plasm-ph2018★ 13 cited

Analytical model of an ion cloud cooled by collisions in a Paul trap

Pierre Delahaye

A simple model of a trapped ion cloud cooled by collisions in a buffer gas in a Paul trap is presented. It is based on the customary decomposition of the ion motion in micro- and m…

nucl-ex2018★ 17 cited

Electron shakeoff following the \b{eta}+ decay of 19Ne+ and 35Ar+ trapped ions

X. Fabian, X. Fléchard, B. Pons +16

The electron shakeoff of 19F and 35Cl atoms resulting from the \b{eta}+ decay of 19Ne+ and 35Ar+ ions has been investigated using a Paul trap coupled to a time of flight recoil-ion…

nucl-ex2017★ 6 cited

High Precision Measurement of the Ne Half-life using real-time digital acquisition

C. Fontbonne, P. Ujić, F. de Oliveira Santos +34

The half-life of Ne has been measured using a real-time digital multiparametric acquisition system providing an accurate time-stamp and relevant information on the detectors…

nucl-ex2017★ 15 cited

Evaluation of fusion-evaporation cross-section calculations

B. Blank, G. Canchel, F. Seis +1

Calculated fusion-evaporation cross sections from five different codes are compared to experimental data. The present comparison extents over a large range of nuclei and isotopic c…

nucl-ex2015★ 19 cited

Precision measurements with LPCTrap at GANIL

E. Lienard, G. Ban, C. Couratin +15

The experimental achievements and the results obtained so far with the LPCTrap device installed at GANIL are presented. The apparatus is dedicated to the study of the weak interact…

physics.ins-det2015★ 8 cited

Extending the applicability of an open-ring trap to perform experiments with a single laser-cooled ion

J. M. Cornejo, M. Colombano, J. Doménech +3

An open-ring ion trap, also referred to as transparent trap was initially built up to perform - correlation experiments with radioactive ions. This trap geometry is also well…

physics.ins-det2014★ 20 cited

High-precision efficiency calibration of a high-purity co-axial germanium detector

B. Blank, J. Souin, P. Ascher +12

A high-purity co-axial germanium detector has been calibrated in efficiency to a precision of about 0.15% over a wide energy range. High-precision scans of the detector crystal and…

nucl-ex2013★ 19 cited

Electron shakeoff following the ?+ decay of trapped 35Ar+ ions

C. Couratin, X. Fabian, B. Fabre +15

The electron shakeoff of Cl atoms resulting from the decay of Ar ions has been investigated using a Paul trap coupled to a recoil-ion spectrometer. The ch…

nucl-ex2010★ 18 cited

First detection and energy measurement of recoil ions following beta decay in a Penning trap with the WITCH experiment

M. Beck, S. Coeck, V. Yu. Kozlov +13

The WITCH experiment (Weak Interaction Trap for CHarged particles) will search for exotic interactions by investigating the beta-neutrino angular correlation via the measurement of…

nucl-ex2008★ 28 cited

The WITCH experiment: Acquiring the first recoil ion spectrum

V. Yu. Kozlov, M. Beck, S. Coeck +12

The standard model of the electroweak interaction describes beta-decay in the well-known V-A form. Nevertheless, the most general Hamiltonian of a beta-decay includes also other po…

physics.ins-det2008★ 8 cited

Electric and magnetic field optimization procedure for Penning trap mass spectrometers

D. Beck, K. Blaum, G. Bollen +8

Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize thes…

nucl-ex2008★ 41 cited

Coulomb excitation of Ni at safe energies

N. Bree, I. Stefanescu, P. A. Butler +29

The value in Ni has been measured using Coulomb excitation at safe energies. The Ni radioactive beam was post-accelerated at the ISOLDE facility (CE…

nucl-ex2008★ 26 cited

Precise half-life measurement of the 26Si ground state

I. Matea, J. Souin, J. Aysto +18

The beta-decay half-life of 26Si was measured with a relative precision of 1.4*10e3. The measurement yields a value of 2.2283(27) s which is in good agreement with previous measure…

nucl-ex2007★ 142 cited

High-precision mass measurements of nickel, copper, and gallium isotopes and the purported shell closure at N=40

C. Guenaut, G. Audi, D. Beck +11

High-precision mass measurements of more than thirty neutron-rich nuclides around the Z=28 closed proton shell were performed with the triple-trap mass spectrometer ISOLTRAP at ISO…