High-precision Penning-trap mass measurements of Cd and In isotopes at JYFLTRAP remove the fluctuations in the two-neutron separation energies
arXiv:2308.15270 · doi:10.1103/PhysRevC.108.064302
Abstract
We report on the first direct mass measurements of the Cd and In isotopes performed at the Ion Guide Isotope Separator On-Line facility using the JYFLTRAP double Penning trap mass spectrometer. The masses of In and Cd isotopes are in agreement with the literature, while In and Cd differ from literature by 49, 13 and 85 keV (6.1, 1.9 and 2.1 standard deviations), respectively. The excitation energy of the In first isomeric state, keV, was determined for the first time. The updated mass values removed the fluctuations observed in the two-neutron separation energies and lead to a smoother linear decrease of both isotopic chains. The value for the Cd decay is also found to increase from 3.93(6) to 4.089(8). The reported results indicate an absence of significant structural changes around .
8 pages, 3 figures
References in corpus (9)
- A sextupole ion beam guide to improve the efficiency and beam quality at IGISOL
- Preparing isomerically pure beams of short-lived nuclei at JYFLTRAP
- Odd-odd neutron-rich rhodium isotopes studied with the double Penning trap JYFLTRAP
- Novel Penning-trap techniques reveal isomeric states in In and In for the first time
- Direct measurement of the mass difference of As-Ge rules out As as a promising -decay candidate to determine the neutrino mass
- Observation of an ultra-low -value electron-capture channel decaying to As via high-precision mass measurement
- Precise Q value measurements of Ag and Cd with the Canadian Penning trap for evaluation of potential ultra-low Q value -decays
- High-precision measurements of low-lying isomeric states in In with JYFLTRAP double Penning trap
- Identification of a potential ultra-low Q value electron capture decay branch in Se via a precise Penning trap measurement of the mass of As
Cited by in corpus (6)
- High Precision Binding Energies from Physics Informed Machine Learning
- Isomeric states of fission fragments explored via Penning trap mass spectrometry at IGISOL
- Mass measurements in the Sn region with the JYFLTRAP double Penning trap mass spectrometer
- Further exploration of binding energy residuals using machine learning and the development of a composite ensemble model
- Binding energies, charge radii, spins and moments: odd-odd Ag isotopes and discovery of a new isomer
- Probing the quantum phase transition around via mass measurements of technetium isotopes