Observation of an ultra-low -value electron-capture channel decaying to As via high-precision mass measurement
arXiv:2203.00457 · doi:10.1103/PhysRevC.106.015501
Abstract
A precise determination of the atomic mass of As has been performed utilizing the double Penning trap mass spectrometer, JYFLTRAP. The mass excess is measured to be -73035.519(42) keV/c, which is a factor of 21 more precise and 1.3(9) keV/c lower than the adopted value in the newest Atomic Mass Evaluation (AME2020). This value has been used to determine the ground-state-to-ground-state electron-capture decay value of Se and decay value of Ge, which are derived to be 866.041(81) keV and 1178.561(65) keV, respectively. Using the nuclear energy-level data of 860.00(40) keV, 865.40(50) keV (final states of electron capture) and 1172.00(60) keV (final state of decay) for the excited states of As, we have determined the ground-state-to-excited-state values for two transitions of Se As and one transition of Ge As. The ground-state-to-excited-state values are determined to be 6.04(41) keV, 0.64(51) keV and 6.56(60) keV, respectively, thus confirming that the three low -value transitions are all energetically valid and one of them is a possible candidate channel for antineutrino mass determination. Furthermore, the ground-state-to-excited-state value of transition Se As (865.40(50) keV) is revealed to be ultra-low (< 1 keV) and the first-ever confirmed EC transition possessing an ultra-low value from direct measurements.
7 pages, 3 figures
References in corpus (5)
- Double Beta Decay, Majorana Neutrinos, and Neutrino Mass
- HOLMES - The Electron Capture Decay of 163Ho to Measure the Electron Neutrino Mass with sub-eV sensitivity
- Dy electron-capture: a strong new candidate for neutrino mass determination
- First direct neutrino-mass measurement with sub-eV sensitivity
- Direct measurement of the mass difference of As-Ge rules out As as a promising -decay candidate to determine the neutrino mass
Cited by in corpus (11)
- Searches for massive neutrinos with mechanical quantum sensors
- Updated evaluation of potential ultra-low Q value -decay candidates
- Precise Q value measurements of Ag and Cd with the Canadian Penning trap for evaluation of potential ultra-low Q value -decays
- High-precision Penning-trap mass measurements of Cd and In isotopes at JYFLTRAP remove the fluctuations in the two-neutron separation energies
- decay -value measurement of Cs and its implications to neutrino studies
- High-precision measurements of low-lying isomeric states in In with JYFLTRAP double Penning trap
- Identification of a potential ultra-low Q value electron capture decay branch in Se via a precise Penning trap measurement of the mass of As
- High-precision measurements of the atomic mass and electron-capture decay value of Tc
- Mass measurements in the Sn region with the JYFLTRAP double Penning trap mass spectrometer
- Ultra-low value for the allowed decay of Ag confirmed via mass measurements
- High-precision direct decay energy measurements of the electron-capture decay of Tc