216 citations · 1.3k across the 66 of their papers we have counts for
66 papers
SPLENDOR: a novel detector platform to search for light dark matter with narrow-gap semiconductors
P. Abbamonte, A. Albert, D. S. M. Alves +31
We present the design and current status of SPLENDOR, a novel detector platform that combines narrow-gap semiconductor targets with low-noise charge readout to achieve sensitivity…
The MAJORANA DEMONSTRATOR experiment's construction, commissioning, and performance
N. Abgrall, E. Aguayo, I. J. Arnquist +108
Background: The MAJORANA DEMONSTRATOR , a modular array of isotopically enriched high-purity germanium (HPGe) detectors, was constructed to demonstrate backgrounds low enough to ju…
Rare multi-nucleon decays with the full data sets of the Majorana Demonstrator
I. J. Arnquist, F. T. Avignone, A. S. Barabash +39
The Majorana Demonstrator was an ultra-low-background experiment designed for neutrinoless double-beta decay () investigation in Ge. Located at the Sanford Underground…
An assay-based background projection for the MAJORANA DEMONSTRATOR using Monte Carlo Uncertainty Propagation
I. J. Arnquist, F. T. Avignone, A. S. Barabash +53
The background index is an important quantity which is used in projecting and calculating the half-life sensitivity of neutrinoless double-beta decay () experiments. A novel…
Two-Stage Cryogenic HEMT Based Amplifier For Low Temperature Detectors
J. Anczarski, M. Dubovskov, C. W. Fink +12
To search for dark matter candidates with masses below (MeV), the SPLENDOR (Search for Particles of Light dark mattEr with Narrow-gap semiconDuctORs) experiment is dev…
Majorana Demonstrator Data Release for AI/ML Applications
I. J. Arnquist, F. T. Avignone, A. S. Barabash +57
The enclosed data release consists of a subset of the calibration data from the Majorana Demonstrator experiment. Each Majorana event is accompanied by raw Germanium detector wavef…
Dark Matter Constraints from Isomeric Hf
D. S. M. Alves, S. R. Elliott, R. Massarczyk +2
We describe a first measurement of the radiation from a Hf sample to search for dark matter. The flux from this sample, possessed by Los Alamos National Laboratory…
Constraints on the decay of Ta
I. J. Arnquist, F. T. Avignone, A. S. Barabash +56
Ta is a rare nuclear isomer whose decay has never been observed. Its remarkably long lifetime surpasses the half-lives of all other known and electron capture decays d…
Energy Calibration of Germanium Detectors for the MAJORANA DEMONSTRATOR
I. J. Arnquist, F. T. Avignone, A. S. Barabash +53
The MAJORANA DEMONSTRATOR was a search for neutrinoless double-beta decay () in the Ge isotope. It was staged at the 4850-foot level of the Sanford Underground Researc…
Neutrinoless Double Beta Decay
C. Adams, K. Alfonso, C. Andreoiu +229
This White Paper, prepared for the Fundamental Symmetries, Neutrons, and Neutrinos Town Meeting related to the 2023 Nuclear Physics Long Range Plan, makes the case for double beta…
Variable Energy X-ray Fluorescence Source
S. R. Elliott, E. M. Bond, B. Dodson +5
We detail the design of a variable energy, x-ray fluorescence source using a low activity (1.8~dpm) \nuc{99}{Tc} source that irradiates thin foils. By rotating the…
Calibration sources for the LEGEND-200 experiment
L. Baudis, G. Benato, E. M. Bond +5
In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the -value of the dec…
Modeling Backgrounds for the MAJORANA DEMONSTRATOR
C. R. Haufe, I. J. Arnquist, F. T. Avignone +55
The MAJORANA DEMONSTRATOR is a neutrinoless double-beta decay () experiment containing 30 kg of p-type point contact germanium detectors enriched to 88% in 76Ge and $\s…
Charge Trapping and Energy Performance of the MAJORANA DEMONSTRATOR
I. J. Arnquist, F. T. Avignone, A. S. Barabash +55
P-type point contact (PPC) high-purity germanium detectors are an important technology in astroparticle and nuclear physics due to their superb energy resolution, low noise, and pu…
Interpretable Boosted Decision Tree Analysis for the Majorana Demonstrator
I. J. Arnquist, F. T. Avignone, A. S. Barabash +52
The Majorana Demonstrator is a leading experiment searching for neutrinoless double-beta decay with high purity germanium detectors (HPGe). Machine learning provides a new way to m…
Final Result of the MAJORANA DEMONSTRATOR's Search for Neutrinoless Double- Decay in Ge
I. J. Arnquist, F. T. Avignone, A. S. Barabash +57
The MAJORANA DEMONSTRATOR searched for neutrinoless double- decay () of Ge using modular arrays of high-purity Ge detectors operated in vacuum cryostats in a low-ba…
Exotic dark matter search with the Majorana Demonstrator
I. J. Arnquist, F. T. Avignone, A. S. Barabash +56
With excellent energy resolution and ultra-low level radiogenic backgrounds, the high-purity germanium detectors in the Majorana Demonstrator enable searches for several classes of…
Search for solar axions via axion-photon coupling with the Majorana Demonstrator
I. J. Arnquist, F. T. Avignone, A. S. Barabash +55
Axions were originally proposed to explain the strong-CP problem in QCD. Through the axion-photon coupling, the Sun could be a major source of axions, which could be measured in so…
Experimental study of 13C(α,n)16O reactions in the Majorana Demonstrator calibration data
MAJORANA Collaboration, I. J. Arnquist, F. T. Avignone +55
Neutron captures and delayed decays of reaction products are common sources of backgrounds in ultra-rare event searches. In this work, we studied C(O reactions in…
Search for charge nonconservation and Pauli exclusion principle violation with the Majorana Demonstrator
MAJORANA Collaboration, I. J. Arnquist, F. T. Avignone +55
Charge conservation and the Pauli exclusion principle result from fundamental symmetries in the standard model of particle physics, and are typically taken as axiomatic. High-preci…
Search for Spontaneous Radiation from Wavefunction Collapse in the Majorana Demonstrator
I. J. Arnquist, F. T. Avignone, A. S. Barabash +51
The Majorana Demonstrator neutrinoless double-beta decay experiment comprises a 44 kg (30 kg enriched in ) array of -type, point-contact germanium detectors. W…
The MAJORANA DEMONSTRATOR Readout Electronics System
N. Abgrall, M. Amman, I. J. Arnquist +76
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Sta…
Signatures of muonic activation in the Majorana Demonstrator
I. J. Arnquist, F. T. Avignone, A. S. Barabash +55
Experiments searching for very rare processes such as neutrinoless double-beta decay require a detailed understanding of all sources of background. Signals from radioactive impurit…
LEGEND-1000 Preconceptual Design Report
LEGEND Collaboration, N. Abgrall, I. Abt +261
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless Decay. This international experiment is designed to answer one o…