193 citations · 262 across the 7 of their papers we have counts for
9 papers
Evaluation of Planar Silicon Pixel Sensors with the RD53A Readout Chip for the Phase-2 Upgrade of the CMS Inner Tracker
The Tracker Group of the CMS Collaboration
The Large Hadron Collider (LHC) at CERN will undergo an upgrade in order to increase its luminosity to cms. The increased luminosity during this…
Test beam performance of a CBC3-based mini-module for the Phase-2 CMS Outer Tracker before and after neutron irradiation
The Tracker Group of the CMS Collaboration
The Large Hadron Collider (LHC) at CERN will undergo major upgrades to increase the instantaneous luminosity up to 5-7.5 cms. This High Luminosity upgr…
Precision measurement of the structure of the CMS inner tracking system using nuclear interactions
CMS Collaboration
The structure of the CMS inner tracking system has been studied using nuclear interactions of hadrons striking its material. Data from proton-proton collisions at a center-of-mass…
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
M. Dragicevic, M. Friedl, J. Hrubec +481
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detecto…
Dose rate effects in the radiation damage of the plastic scintillators of the CMS Hadron Endcap Calorimeter
HCAL collaboration
We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that the…
Performance of the EUDET-type beam telescopes
H. Jansen, S. Spannagel, J. Behr +16
Test beam measurements at the test beam facilities of DESY have been conducted to characterise the performance of the EUDET-type beam telescopes originally developed within the EUD…
Impact of low-dose electron irradiation on n+p silicon strip sensors
The Tracker Group of the CMS Collaboration
The response of n+p silicon strip sensors to electrons from a Sr-90 source was measured using a multi-channel read-out system with 25 ns sampling time. The measurements were perfor…
Infrastructure for Detector Research and Development towards the International Linear Collider
J. Aguilar, P. Ambalathankandy, T. Fiutowski +274
The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to…
Design and Test of a Forward Neutron Calorimeter for the ZEUS Experiment
The ZEUS FNC Group, S. Bhadra, I. Bohnet +20
A lead scintillator sandwich sampling calorimeter has been installed in the HERA tunnel 105.6 m from the central ZEUS detector in the proton beam direction. It is designed to measu…